{"product_id":"132f0058-danfoss-vlt-micro-drive-fc-51-11kw","title":"132F0058 VLT Micro Drive FC 51 11kW 380–480V IP20 Frequency Converter | Danfoss","description":"\u003cp data-inspector-id=\"html:73d075d7:3\"\u003eThe Original New Danfoss 132F0058 (FC-051P11KT4E20H3BXCXXXSXXX) VLT® Micro Drive FC 51 is an 11 kW (15 HP) three-phase drive for 380–480 V supplies, built for panel builders and machine builders who need compact, dependable motor control at low installation cost. In the M4 frame it delivers 23 A continuous output at 380–440 V and 21 A at 440–480 V, with 150% overload for one minute.\u003c\/p\u003e\n\u003cp data-inspector-id=\"html:73d075d7:4\"\u003eThe model code specifies the H3 RFI filter, a built-in brake chopper, coated PCBs and no local control panel, so the drive is normally set up from a PLC, a fieldbus network or an optional LCP 11 \/ LCP 12 panel. RS-485 communication supports Modbus RTU and the Danfoss FC protocol, the control terminals provide five digital inputs, two analog inputs, one analog output and one relay output, and parameters can be set or backed up from a PC with the VLT Motion Control Tool MCT 10.\u003c\/p\u003e\n\u003cp data-inspector-id=\"html:73d075d7:5\"\u003eMotor control is sensorless vector (VVC\u003csup data-inspector-id=\"html:73d075d7:6\"\u003e+\u003c\/sup\u003e) or V\/f, with automatic motor tuning, automatic energy optimisation, flying start, electronic thermal relay and a PI process controller built in. The compact book-style housing allows side-by-side mounting for IP20 units, with at least 100 mm free above and below the drive for cooling airflow. Conformally coated PCBs (IEC 60721-3-3 Class 3C3) provide additional protection for the internal electronics against humidity, corrosive gases and aggressive atmospheres; the enclosure rating remains IP20, so the drive should still be mounted in a suitable cabinet, especially where dust is present.\u003c\/p\u003e\n\u003cp data-inspector-id=\"html:73d075d7:7\"\u003eAt 125 × 292 × 241 mm and 6.0 kg, the M4 frame fits where larger drives will not, while the built-in RFI filter limits radio disturbance from motor cables. Note that the H3 filter class is specified with a reduced motor cable length; check the Danfoss cable length table during panel design.\u003c\/p\u003e\n\u003cp data-inspector-id=\"html:73d075d7:8\"\u003e\u003cstrong data-inspector-id=\"html:73d075d7:9\"\u003eCore engineering highlights:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eVLT Micro Drive FC 51 | 11 kW \/ 15 HP | Three-phase 380–480 V AC | 23 A continuous output at 380–440 V, 21 A at 440–480 V | 150% overload for 60 s | IP20 \/ Chassis, M4 frame | 125 × 292 × 241 mm, 6.0 kg | H3 RFI filter, class A1\/B (C1) | Built-in brake chopper | Coated PCB | No LCP included | RS-485 with Modbus RTU and FC protocol | VVC+ sensorless vector and V\/f control | PI process controller, AEO and AMT | Estimated power loss 290 W best case \/ 342 W typical, efficiency 97.8% \/ 97.4% at rated load | Side-by-side mounting possible, 100 mm clearance above and below | Compact, low-cost general-purpose drive\u003c\/p\u003e\n\u003ch2 data-inspector-id=\"html:73d075d7:10\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-inspector-id=\"html:73d075d7:11\"\u003e\n\u003cli data-inspector-id=\"html:73d075d7:12\"\u003eOriginal New Danfoss 132F0058 VLT Micro Drive FC 51 frequency converter.\u003c\/li\u003e\n\u003cli data-inspector-id=\"html:73d075d7:13\"\u003e11 kW \/ 15 HP rating for three-phase 380–480 V AC supplies.\u003c\/li\u003e\n\u003cli data-inspector-id=\"html:73d075d7:14\"\u003e23 A continuous output current at 380–440 V and 21 A at 440–480 V.\u003c\/li\u003e\n\u003cli data-inspector-id=\"html:73d075d7:15\"\u003e150% overload for 60 seconds (34.5 A \/ 31.5 A intermittent) for heavy starts.\u003c\/li\u003e\n\u003cli data-inspector-id=\"html:73d075d7:16\"\u003eIP20 \/ Chassis enclosure in the M4 frame, 125 × 292 × 241 mm, 6.0 kg.\u003c\/li\u003e\n\u003cli data-inspector-id=\"html:73d075d7:17\"\u003eBuilt-in H3 RFI filter, class A1\/B (C1), reducing radio disturbance from motor cables.\u003c\/li\u003e\n\u003cli data-inspector-id=\"html:73d075d7:18\"\u003eBuilt-in brake chopper for dynamic braking with a suitable external brake resistor.\u003c\/li\u003e\n\u003cli data-inspector-id=\"html:73d075d7:19\"\u003eEstimated power loss 290 W best case \/ 342 W typical at rated load, efficiency 97.8% \/ 97.4%, supporting cabinet cooling design.\u003c\/li\u003e\n\u003cli data-inspector-id=\"html:73d075d7:20\"\u003eConformally coated PCBs (IEC 60721-3-3 Class 3C3) for protection against humidity, corrosive gases and aggressive atmospheres; enclosure rating remains IP20.\u003c\/li\u003e\n\u003cli data-inspector-id=\"html:73d075d7:21\"\u003eSensorless vector control (VVC\u003csup data-inspector-id=\"html:73d075d7:22\"\u003e+\u003c\/sup\u003e) or V\/f, selectable per application.\u003c\/li\u003e\n\u003cli data-inspector-id=\"html:73d075d7:23\"\u003eAutomatic Motor Tuning (AMT) to match the drive to the connected motor.\u003c\/li\u003e\n\u003cli data-inspector-id=\"html:73d075d7:24\"\u003eAutomatic Energy Optimizer (AEO) for reduced energy consumption at partial load.\u003c\/li\u003e\n\u003cli data-inspector-id=\"html:73d075d7:25\"\u003eIntegrated PI process controller for pressure, flow, level or temperature loops.\u003c\/li\u003e\n\u003cli data-inspector-id=\"html:73d075d7:26\"\u003eFlying start for catching a spinning motor, and electronic thermal relay (ETR) motor protection.\u003c\/li\u003e\n\u003cli data-inspector-id=\"html:73d075d7:27\"\u003eSmart Logic Controller for simple sequence logic without an external PLC.\u003c\/li\u003e\n\u003cli data-inspector-id=\"html:73d075d7:28\"\u003eRS-485 port supporting Modbus RTU and Danfoss FC protocol for PLC and SCADA integration.\u003c\/li\u003e\n\u003cli data-inspector-id=\"html:73d075d7:29\"\u003eFive digital inputs, two analog inputs, one analog output and one relay output.\u003c\/li\u003e\n\u003cli data-inspector-id=\"html:73d075d7:30\"\u003eSide-by-side mounting possible for IP20 units to save panel width, with at least 100 mm clearance above and below for cooling airflow.\u003c\/li\u003e\n\u003cli data-inspector-id=\"html:73d075d7:31\"\u003eNo local control panel included; LCP 11 or LCP 12 can be added as an accessory.\u003c\/li\u003e\n\u003cli data-inspector-id=\"html:73d075d7:32\"\u003eParameter setting and backup through the optional LCP or the VLT Motion Control Tool MCT 10.\u003c\/li\u003e\n\u003cli data-inspector-id=\"html:73d075d7:33\"\u003eEffective heat-sink design that removes heat from the electronics and extends service life.\u003c\/li\u003e\n\u003cli data-inspector-id=\"html:73d075d7:34\"\u003eCompact, low-cost general-purpose drive for OEM machines and standard panels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-inspector-id=\"html:73d075d7:35\"\u003eApplications\u003c\/h2\u003e\n\u003cul data-inspector-id=\"html:73d075d7:36\"\u003e\n\u003cli data-inspector-id=\"html:73d075d7:37\"\u003eConveyors and small material handling equipment.\u003c\/li\u003e\n\u003cli data-inspector-id=\"html:73d075d7:38\"\u003eFans, blowers and centrifugal pumps.\u003c\/li\u003e\n\u003cli data-inspector-id=\"html:73d075d7:39\"\u003eMixers, agitators and small processing machines.\u003c\/li\u003e\n\u003cli data-inspector-id=\"html:73d075d7:40\"\u003ePackaging, labeling and filling machines.\u003c\/li\u003e\n\u003cli data-inspector-id=\"html:73d075d7:41\"\u003eWoodworking, textile and plastic machinery.\u003c\/li\u003e\n\u003cli data-inspector-id=\"html:73d075d7:42\"\u003eMachine tools and auxiliary drives in OEM equipment.\u003c\/li\u003e\n\u003cli data-inspector-id=\"html:73d075d7:43\"\u003eWater and wastewater pumps with PI process control.\u003c\/li\u003e\n\u003cli data-inspector-id=\"html:73d075d7:44\"\u003ePanels where space, depth and cost are constrained.\u003c\/li\u003e\n\u003cli data-inspector-id=\"html:73d075d7:45\"\u003eMachines controlled from a PLC over Modbus RTU.\u003c\/li\u003e\n\u003cli data-inspector-id=\"html:73d075d7:46\"\u003eReplacement of existing FC 51 drives in installed machinery.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-inspector-id=\"html:73d075d7:47\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable data-inspector-id=\"html:73d075d7:48\"\u003e\n\u003cthead data-inspector-id=\"html:73d075d7:49\"\u003e\n\u003ctr data-inspector-id=\"html:73d075d7:50\"\u003e\n\u003cth data-inspector-id=\"html:73d075d7:51\"\u003eAttribute\u003c\/th\u003e\n\u003cth data-inspector-id=\"html:73d075d7:52\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-inspector-id=\"html:73d075d7:53\"\u003e\n\u003ctr data-inspector-id=\"html:73d075d7:54\"\u003e\n\u003cth scope=\"row\" data-inspector-id=\"html:73d075d7:55\"\u003eOrdering Number\u003c\/th\u003e\n\u003ctd data-inspector-id=\"html:73d075d7:56\"\u003e132F0058\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-inspector-id=\"html:73d075d7:57\"\u003e\n\u003cth scope=\"row\" data-inspector-id=\"html:73d075d7:58\"\u003eProduct Type Designation\u003c\/th\u003e\n\u003ctd data-inspector-id=\"html:73d075d7:59\"\u003eVLT Micro Drive FC 51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-inspector-id=\"html:73d075d7:60\"\u003e\n\u003cth scope=\"row\" data-inspector-id=\"html:73d075d7:61\"\u003eProduct Family\u003c\/th\u003e\n\u003ctd data-inspector-id=\"html:73d075d7:62\"\u003eDanfoss VLT Micro Drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-inspector-id=\"html:73d075d7:63\"\u003e\n\u003cth scope=\"row\" data-inspector-id=\"html:73d075d7:64\"\u003eProduct Category\u003c\/th\u003e\n\u003ctd data-inspector-id=\"html:73d075d7:65\"\u003eDrives, Motors \u0026amp; Controls\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-inspector-id=\"html:73d075d7:66\"\u003e\n\u003cth scope=\"row\" data-inspector-id=\"html:73d075d7:67\"\u003eProduct Type\u003c\/th\u003e\n\u003ctd data-inspector-id=\"html:73d075d7:68\"\u003eVariable Frequency Drive (VFD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-inspector-id=\"html:73d075d7:69\"\u003e\n\u003cth scope=\"row\" data-inspector-id=\"html:73d075d7:70\"\u003eSeries\u003c\/th\u003e\n\u003ctd data-inspector-id=\"html:73d075d7:71\"\u003eFC 51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-inspector-id=\"html:73d075d7:72\"\u003e\n\u003cth scope=\"row\" data-inspector-id=\"html:73d075d7:73\"\u003eFull Model Code\u003c\/th\u003e\n\u003ctd data-inspector-id=\"html:73d075d7:74\"\u003eFC-051P11KT4E20H3BXCXXXSXXX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-inspector-id=\"html:73d075d7:75\"\u003e\n\u003cth scope=\"row\" data-inspector-id=\"html:73d075d7:76\"\u003eRated Output Power\u003c\/th\u003e\n\u003ctd data-inspector-id=\"html:73d075d7:77\"\u003e11 kW \/ 15 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-inspector-id=\"html:73d075d7:78\"\u003e\n\u003cth scope=\"row\" data-inspector-id=\"html:73d075d7:79\"\u003ePower Rating Code\u003c\/th\u003e\n\u003ctd data-inspector-id=\"html:73d075d7:80\"\u003eP11K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-inspector-id=\"html:73d075d7:81\"\u003e\n\u003cth scope=\"row\" data-inspector-id=\"html:73d075d7:82\"\u003eNumber of Phases\u003c\/th\u003e\n\u003ctd data-inspector-id=\"html:73d075d7:83\"\u003eThree-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-inspector-id=\"html:73d075d7:84\"\u003e\n\u003cth scope=\"row\" data-inspector-id=\"html:73d075d7:85\"\u003eSupply Voltage\u003c\/th\u003e\n\u003ctd data-inspector-id=\"html:73d075d7:86\"\u003e380–480 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-inspector-id=\"html:73d075d7:87\"\u003e\n\u003cth scope=\"row\" data-inspector-id=\"html:73d075d7:88\"\u003eSupply Frequency\u003c\/th\u003e\n\u003ctd data-inspector-id=\"html:73d075d7:89\"\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-inspector-id=\"html:73d075d7:90\"\u003e\n\u003cth scope=\"row\" data-inspector-id=\"html:73d075d7:91\"\u003eContinuous Output Current\u003c\/th\u003e\n\u003ctd data-inspector-id=\"html:73d075d7:92\"\u003e23 A at 380–440 V \/ 21 A at 440–480 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-inspector-id=\"html:73d075d7:93\"\u003e\n\u003cth scope=\"row\" data-inspector-id=\"html:73d075d7:94\"\u003eIntermittent Output Current\u003c\/th\u003e\n\u003ctd data-inspector-id=\"html:73d075d7:95\"\u003e34.5 A at 380–440 V \/ 31.5 A at 440–480 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-inspector-id=\"html:73d075d7:96\"\u003e\n\u003cth scope=\"row\" data-inspector-id=\"html:73d075d7:97\"\u003eOverload Capability\u003c\/th\u003e\n\u003ctd data-inspector-id=\"html:73d075d7:98\"\u003e150% for 60 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-inspector-id=\"html:73d075d7:99\"\u003e\n\u003cth scope=\"row\" data-inspector-id=\"html:73d075d7:100\"\u003eContinuous Input Current\u003c\/th\u003e\n\u003ctd data-inspector-id=\"html:73d075d7:101\"\u003e33 A at 380–440 V \/ 29 A at 440–480 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-inspector-id=\"html:73d075d7:102\"\u003e\n\u003cth scope=\"row\" data-inspector-id=\"html:73d075d7:103\"\u003eIntermittent Input Current\u003c\/th\u003e\n\u003ctd data-inspector-id=\"html:73d075d7:104\"\u003e47.5 A at 380–440 V \/ 41 A at 440–480 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-inspector-id=\"html:73d075d7:105\"\u003e\n\u003cth scope=\"row\" data-inspector-id=\"html:73d075d7:106\"\u003eEstimated Power Loss\u003c\/th\u003e\n\u003ctd data-inspector-id=\"html:73d075d7:107\"\u003e290 W best case \/ 342 W typical at rated load, default switching frequency\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-inspector-id=\"html:73d075d7:108\"\u003e\n\u003cth scope=\"row\" data-inspector-id=\"html:73d075d7:109\"\u003eEfficiency at Rated Load\u003c\/th\u003e\n\u003ctd data-inspector-id=\"html:73d075d7:110\"\u003e97.8% best case \/ 97.4% typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-inspector-id=\"html:73d075d7:111\"\u003e\n\u003cth scope=\"row\" data-inspector-id=\"html:73d075d7:112\"\u003eMaximum Motor Cable Size\u003c\/th\u003e\n\u003ctd data-inspector-id=\"html:73d075d7:113\"\u003e16 mm² \/ AWG 6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-inspector-id=\"html:73d075d7:114\"\u003e\n\u003cth scope=\"row\" data-inspector-id=\"html:73d075d7:115\"\u003eMotor Control Principle\u003c\/th\u003e\n\u003ctd data-inspector-id=\"html:73d075d7:116\"\u003eVVC\u003csup data-inspector-id=\"html:73d075d7:117\"\u003e+\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003esensorless vector and V\/f (U\/f)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-inspector-id=\"html:73d075d7:118\"\u003e\n\u003cth scope=\"row\" data-inspector-id=\"html:73d075d7:119\"\u003eEnclosure Rating\u003c\/th\u003e\n\u003ctd data-inspector-id=\"html:73d075d7:120\"\u003eIP20 \/ Chassis (E20)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-inspector-id=\"html:73d075d7:121\"\u003e\n\u003cth scope=\"row\" data-inspector-id=\"html:73d075d7:122\"\u003eFrame Size\u003c\/th\u003e\n\u003ctd data-inspector-id=\"html:73d075d7:123\"\u003eM4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-inspector-id=\"html:73d075d7:124\"\u003e\n\u003cth scope=\"row\" data-inspector-id=\"html:73d075d7:125\"\u003eDimensions (W × H × D)\u003c\/th\u003e\n\u003ctd data-inspector-id=\"html:73d075d7:126\"\u003e125 × 292 × 241 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-inspector-id=\"html:73d075d7:127\"\u003e\n\u003cth scope=\"row\" data-inspector-id=\"html:73d075d7:128\"\u003eMounting Clearance\u003c\/th\u003e\n\u003ctd data-inspector-id=\"html:73d075d7:129\"\u003eSide-by-side mounting possible for IP20 units; at least 100 mm free above and below for cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-inspector-id=\"html:73d075d7:130\"\u003e\n\u003cth scope=\"row\" data-inspector-id=\"html:73d075d7:131\"\u003eRFI Filter\u003c\/th\u003e\n\u003ctd data-inspector-id=\"html:73d075d7:132\"\u003eH3, class A1\/B (C1), specified with reduced motor cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-inspector-id=\"html:73d075d7:133\"\u003e\n\u003cth scope=\"row\" data-inspector-id=\"html:73d075d7:134\"\u003eBrake Chopper\u003c\/th\u003e\n\u003ctd data-inspector-id=\"html:73d075d7:135\"\u003eBuilt-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-inspector-id=\"html:73d075d7:136\"\u003e\n\u003cth scope=\"row\" data-inspector-id=\"html:73d075d7:137\"\u003eLocal Control Panel\u003c\/th\u003e\n\u003ctd data-inspector-id=\"html:73d075d7:138\"\u003eNot included; LCP 11 (132B0100) or LCP 12 (132B0101) optional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-inspector-id=\"html:73d075d7:139\"\u003e\n\u003cth scope=\"row\" data-inspector-id=\"html:73d075d7:140\"\u003ePCB Protection\u003c\/th\u003e\n\u003ctd data-inspector-id=\"html:73d075d7:141\"\u003eCoated PCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-inspector-id=\"html:73d075d7:142\"\u003e\n\u003cth scope=\"row\" data-inspector-id=\"html:73d075d7:143\"\u003eMains Option\u003c\/th\u003e\n\u003ctd data-inspector-id=\"html:73d075d7:144\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-inspector-id=\"html:73d075d7:145\"\u003e\n\u003cth scope=\"row\" data-inspector-id=\"html:73d075d7:146\"\u003eSerial Communication\u003c\/th\u003e\n\u003ctd data-inspector-id=\"html:73d075d7:147\"\u003eRS-485: Modbus RTU, Danfoss FC protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-inspector-id=\"html:73d075d7:148\"\u003e\n\u003cth scope=\"row\" data-inspector-id=\"html:73d075d7:149\"\u003eDigital Inputs\u003c\/th\u003e\n\u003ctd data-inspector-id=\"html:73d075d7:150\"\u003e5 programmable digital inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-inspector-id=\"html:73d075d7:151\"\u003e\n\u003cth scope=\"row\" data-inspector-id=\"html:73d075d7:152\"\u003eAnalog Inputs\u003c\/th\u003e\n\u003ctd data-inspector-id=\"html:73d075d7:153\"\u003e2 (0–10 V; one configurable for 0\/4–20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-inspector-id=\"html:73d075d7:154\"\u003e\n\u003cth scope=\"row\" data-inspector-id=\"html:73d075d7:155\"\u003eAnalog Outputs\u003c\/th\u003e\n\u003ctd data-inspector-id=\"html:73d075d7:156\"\u003e1 (0\/4–20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-inspector-id=\"html:73d075d7:157\"\u003e\n\u003cth scope=\"row\" data-inspector-id=\"html:73d075d7:158\"\u003eRelay Outputs\u003c\/th\u003e\n\u003ctd data-inspector-id=\"html:73d075d7:159\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-inspector-id=\"html:73d075d7:160\"\u003e\n\u003cth scope=\"row\" data-inspector-id=\"html:73d075d7:161\"\u003eProcess Controller\u003c\/th\u003e\n\u003ctd data-inspector-id=\"html:73d075d7:162\"\u003eIntegrated PI controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-inspector-id=\"html:73d075d7:163\"\u003e\n\u003cth scope=\"row\" data-inspector-id=\"html:73d075d7:164\"\u003eAmbient Temperature\u003c\/th\u003e\n\u003ctd data-inspector-id=\"html:73d075d7:165\"\u003eUp to 50 °C ambient with derating; continuous full load at 50 °C reduces drive lifetime\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-inspector-id=\"html:73d075d7:166\"\u003e\n\u003cth scope=\"row\" data-inspector-id=\"html:73d075d7:167\"\u003eAltitude\u003c\/th\u003e\n\u003ctd data-inspector-id=\"html:73d075d7:168\"\u003eNo derating below 1000 m; reduce output 1% per 100 m above 1000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-inspector-id=\"html:73d075d7:169\"\u003e\n\u003cth scope=\"row\" data-inspector-id=\"html:73d075d7:170\"\u003eNet Weight\u003c\/th\u003e\n\u003ctd data-inspector-id=\"html:73d075d7:171\"\u003e6.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-inspector-id=\"html:73d075d7:172\"\u003e\n\u003cth scope=\"row\" data-inspector-id=\"html:73d075d7:173\"\u003eGross Weight\u003c\/th\u003e\n\u003ctd data-inspector-id=\"html:73d075d7:174\"\u003e6.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-inspector-id=\"html:73d075d7:175\"\u003e\n\u003cth scope=\"row\" data-inspector-id=\"html:73d075d7:176\"\u003eEAN \/ GTIN\u003c\/th\u003e\n\u003ctd data-inspector-id=\"html:73d075d7:177\"\u003e5702427554443\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-inspector-id=\"html:73d075d7:178\"\u003e\n\u003cth scope=\"row\" data-inspector-id=\"html:73d075d7:179\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd data-inspector-id=\"html:73d075d7:180\"\u003eDanfoss\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-inspector-id=\"html:73d075d7:181\"\u003e\n\u003cth scope=\"row\" data-inspector-id=\"html:73d075d7:182\"\u003eProduct Brand\u003c\/th\u003e\n\u003ctd data-inspector-id=\"html:73d075d7:183\"\u003eVLT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 data-inspector-id=\"html:73d075d7:184\"\u003eType Code Decoder\u003c\/h2\u003e\n\u003cp data-inspector-id=\"html:73d075d7:185\"\u003eThe full model code FC-051P11KT4E20H3BXCXXXSXXX is decoded as follows, so the exact configuration can be confirmed before ordering or replacing a drive.\u003c\/p\u003e\n\u003ctable data-inspector-id=\"html:73d075d7:186\"\u003e\n\u003cthead data-inspector-id=\"html:73d075d7:187\"\u003e\n\u003ctr data-inspector-id=\"html:73d075d7:188\"\u003e\n\u003cth data-inspector-id=\"html:73d075d7:189\"\u003eCode\u003c\/th\u003e\n\u003cth data-inspector-id=\"html:73d075d7:190\"\u003eMeaning\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-inspector-id=\"html:73d075d7:191\"\u003e\n\u003ctr data-inspector-id=\"html:73d075d7:192\"\u003e\n\u003cth scope=\"row\" data-inspector-id=\"html:73d075d7:193\"\u003eFC-051\u003c\/th\u003e\n\u003ctd data-inspector-id=\"html:73d075d7:194\"\u003eVLT Micro Drive FC 51 series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-inspector-id=\"html:73d075d7:195\"\u003e\n\u003cth scope=\"row\" data-inspector-id=\"html:73d075d7:196\"\u003eP11K\u003c\/th\u003e\n\u003ctd data-inspector-id=\"html:73d075d7:197\"\u003e11 kW \/ 15 HP output rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-inspector-id=\"html:73d075d7:198\"\u003e\n\u003cth scope=\"row\" data-inspector-id=\"html:73d075d7:199\"\u003eT4\u003c\/th\u003e\n\u003ctd data-inspector-id=\"html:73d075d7:200\"\u003eThree-phase, 380–480 V AC supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-inspector-id=\"html:73d075d7:201\"\u003e\n\u003cth scope=\"row\" data-inspector-id=\"html:73d075d7:202\"\u003eE20\u003c\/th\u003e\n\u003ctd data-inspector-id=\"html:73d075d7:203\"\u003eIP20 \/ Chassis enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-inspector-id=\"html:73d075d7:204\"\u003e\n\u003cth scope=\"row\" data-inspector-id=\"html:73d075d7:205\"\u003eH3\u003c\/th\u003e\n\u003ctd data-inspector-id=\"html:73d075d7:206\"\u003eBuilt-in RFI filter, class A1\/B (C1), reduced motor cable length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-inspector-id=\"html:73d075d7:207\"\u003e\n\u003cth scope=\"row\" data-inspector-id=\"html:73d075d7:208\"\u003eB\u003c\/th\u003e\n\u003ctd data-inspector-id=\"html:73d075d7:209\"\u003eBuilt-in brake chopper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-inspector-id=\"html:73d075d7:210\"\u003e\n\u003cth scope=\"row\" data-inspector-id=\"html:73d075d7:211\"\u003eX\u003c\/th\u003e\n\u003ctd data-inspector-id=\"html:73d075d7:212\"\u003eNo local control panel (LCP 11 \/ LCP 12 optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-inspector-id=\"html:73d075d7:213\"\u003e\n\u003cth scope=\"row\" data-inspector-id=\"html:73d075d7:214\"\u003eC\u003c\/th\u003e\n\u003ctd data-inspector-id=\"html:73d075d7:215\"\u003eCoated PCB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-inspector-id=\"html:73d075d7:216\"\u003e\n\u003cth scope=\"row\" data-inspector-id=\"html:73d075d7:217\"\u003eX (mains option)\u003c\/th\u003e\n\u003ctd data-inspector-id=\"html:73d075d7:218\"\u003eNo mains option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-inspector-id=\"html:73d075d7:219\"\u003e\n\u003cth scope=\"row\" data-inspector-id=\"html:73d075d7:220\"\u003eX (adaptation A)\u003c\/th\u003e\n\u003ctd data-inspector-id=\"html:73d075d7:221\"\u003eStandard cable entries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-inspector-id=\"html:73d075d7:222\"\u003e\n\u003cth scope=\"row\" data-inspector-id=\"html:73d075d7:223\"\u003eX (adaptation B)\u003c\/th\u003e\n\u003ctd data-inspector-id=\"html:73d075d7:224\"\u003eNo additional adaptation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-inspector-id=\"html:73d075d7:225\"\u003e\n\u003cth scope=\"row\" data-inspector-id=\"html:73d075d7:226\"\u003eSXXX\u003c\/th\u003e\n\u003ctd data-inspector-id=\"html:73d075d7:227\"\u003eLatest standard software release\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 data-inspector-id=\"html:73d075d7:228\"\u003eSystem Compatibility\u003c\/h2\u003e\n\u003cul data-inspector-id=\"html:73d075d7:229\"\u003e\n\u003cli data-inspector-id=\"html:73d075d7:230\"\u003eDesigned for three-phase 380–480 V AC industrial motor-control systems with standard induction motors.\u003c\/li\u003e\n\u003cli data-inspector-id=\"html:73d075d7:231\"\u003eVVC\u003csup data-inspector-id=\"html:73d075d7:232\"\u003e+\u003c\/sup\u003e\u003cspan\u003e \u003c\/span\u003esensorless vector or V\/f control, selectable to suit the load type.\u003c\/li\u003e\n\u003cli data-inspector-id=\"html:73d075d7:233\"\u003eRS-485 port supporting Modbus RTU and Danfoss FC protocol for PLC, HMI and SCADA networks.\u003c\/li\u003e\n\u003cli data-inspector-id=\"html:73d075d7:234\"\u003eFive digital inputs, two analog inputs, one analog output and one relay output for stand-alone control.\u003c\/li\u003e\n\u003cli data-inspector-id=\"html:73d075d7:235\"\u003eBuilt-in brake chopper accepts a suitable external Danfoss brake resistor for dynamic braking.\u003c\/li\u003e\n\u003cli data-inspector-id=\"html:73d075d7:236\"\u003eH3 RFI filter class is specified with a reduced motor cable length; check the Danfoss cable length table and use screened motor cable for EMC compliance.\u003c\/li\u003e\n\u003cli data-inspector-id=\"html:73d075d7:237\"\u003eIP20 units can be mounted side-by-side; keep at least 100 mm free above and below the drive for cooling airflow.\u003c\/li\u003e\n\u003cli data-inspector-id=\"html:73d075d7:238\"\u003eDerating applies above 40 °C ambient and above 1000 m installation altitude; the drive is designed for a maximum of 50 °C ambient with reduced load.\u003c\/li\u003e\n\u003cli data-inspector-id=\"html:73d075d7:239\"\u003eNo local control panel is fitted: add LCP 11 (132B0100), LCP 12 (132B0101) or the LCP remote mounting kit (132B0102) for local operation or panel-door access.\u003c\/li\u003e\n\u003cli data-inspector-id=\"html:73d075d7:240\"\u003eParameter setting and backup through the optional LCP or the VLT Motion Control Tool MCT 10.\u003c\/li\u003e\n\u003cli data-inspector-id=\"html:73d075d7:241\"\u003eThe FC 51 does not provide a Safe Torque Off function; machine safety must be implemented by external safety devices.\u003c\/li\u003e\n\u003cli data-inspector-id=\"html:73d075d7:242\"\u003eConfirm motor current, cable length, brake resistor selection, ambient temperature and fieldbus settings before commissioning.\u003c\/li\u003e\n\u003cli data-inspector-id=\"html:73d075d7:243\"\u003eInstallation and servicing must follow Danfoss instructions and be performed by qualified personnel.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-inspector-id=\"html:73d075d7:244\"\u003eRelated Products\u003c\/h2\u003e\n\u003cul data-inspector-id=\"html:73d075d7:245\"\u003e\n\u003cli data-inspector-id=\"html:73d075d7:246\"\u003e132B0100 – VLT Control Panel LCP 11 without potentiometer, IP20 \/ front IP54, numerical display with copy function.\u003c\/li\u003e\n\u003cli data-inspector-id=\"html:73d075d7:247\"\u003e132B0101 – VLT Control Panel LCP 12 with potentiometer, IP20 \/ front IP54.\u003c\/li\u003e\n\u003cli data-inspector-id=\"html:73d075d7:248\"\u003e132B0102 – LCP remote mounting kit with 3 m cable for panel-door installation of LCP 11 or LCP 12.\u003c\/li\u003e\n\u003cli data-inspector-id=\"html:73d075d7:249\"\u003e132B0131 – VLT protection blank cover for drives supplied without an LCP, protecting the panel connector.\u003c\/li\u003e\n\u003cli data-inspector-id=\"html:73d075d7:250\"\u003e132B0120 – NEMA 1 \/ Type 1 conversion kit for the M4 frame, for enclosure conversion when the drive is installed outside a cabinet (the IP21 \/ Type 1 kits 132B0108 and 132B0109 are for M1 and M2 frames only).\u003c\/li\u003e\n\u003cli data-inspector-id=\"html:73d075d7:251\"\u003e132B0122 – De-coupling plate kit for M4 and M5 frames, for screened motor cable connection and EMC performance.\u003c\/li\u003e\n\u003cli data-inspector-id=\"html:73d075d7:252\"\u003e136N8935 – VLT Micro Drive FC 51 7.5 kW, IP20, brake chopper, without RFI filter.\u003c\/li\u003e\n\u003cli data-inspector-id=\"html:73d075d7:253\"\u003e132F0017 – VLT Micro Drive FC 51 0.37 kW, IP20, RFI filter, M1 frame.\u003c\/li\u003e\n\u003cli data-inspector-id=\"html:73d075d7:254\"\u003eDanfoss VLT brake resistors (MCE 101 range) – external dynamic braking resistors; the correct type must be selected according to braking torque, resistance value, braking power and duty cycle.\u003c\/li\u003e\n\u003cli data-inspector-id=\"html:73d075d7:255\"\u003eVLT Midi Drive FC 280 and VLT AutomationDrive FC 302 – higher-performance platforms when the application needs more I\/O, fieldbus options or safety functions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-inspector-id=\"html:73d075d7:256\"\u003ePLC ERA is an independent industrial automation distributor supplying genuine Original New products through established global supply channels. All products are factory sealed when applicable and undergo quality inspection prior to shipment. Danfoss and VLT are registered trademarks of Danfoss A\/S.\u003c\/p\u003e","brand":"Danfoss","offers":[{"title":"Default Title","offer_id":68251169521983,"sku":"132F0058\/ FC-051P11KT4E20H3BXCXXXSXXX","price":457.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0872\/9477\/1519\/files\/danfoss-132f0058-vlt-micro-drive-fc-51-11kw-original-new.jpg?v=1795690324","url":"https:\/\/plcera.com\/ar\/products\/132f0058-danfoss-vlt-micro-drive-fc-51-11kw","provider":"PLC ERA","version":"1.0","type":"link"}