{"product_id":"atv12h037m2-schneider-electric-altivar-12-0-37kw-variable-speed-drive","title":"ATV12H037M2 Altivar 12 0.37 kW 200–240 V Single-Phase Variable Speed Drive | Schneider Electric","description":"\u003cp data-pm-slice=\"1 1 []\"\u003e\u003cspan\u003eThe Original New Schneider Electric ATV12H037M2 Altivar 12 is a compact variable speed drive designed for controlling three-phase asynchronous motors in simple industrial machinery and automation applications. Rated at 0.37 kW (0.55 HP), it operates with a single-phase 200–240 V AC power supply and delivers a continuous three-phase output current of 2.4 A at the nominal 4 kHz switching frequency.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFeaturing an integrated EMC filter, built-in heat sink, and IP20 enclosure, the Altivar 12 provides a compact motor-control solution for electrical cabinets and machinery installations. Its sensorless flux vector control, linear voltage\/frequency control, and quadratic V\/f control modes support flexible motor operation. Adjustable acceleration and deceleration ramps allow motor starting and stopping characteristics to be configured according to application requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe drive incorporates four programmable logic inputs, two logic outputs, one analog input, one analog output, and one relay output. Its built-in two-wire RS-485 interface with an RJ45 connector supports Modbus RTU communication, enabling integration with compatible PLCs, industrial controllers, and automation equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAdditional functions include adjustable motor slip compensation, DC injection braking, and integrated motor thermal protection using continuous I²t calculation. The compact M2-frame heat-sink design, without a built-in cooling fan, makes the ATV12H037M2 suitable for small industrial machines requiring reliable variable-speed motor control from a single-phase electrical supply.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eCore Engineering Highlights:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e0.37 kW \/ 0.55 HP rated motor power | Single-phase 200–240 V AC input | Three-phase 200–240 V AC motor output | 2.4 A continuous output current at 4 kHz | 3.6 A transient output current for 60 seconds | Integrated EMC filter | IP20 enclosure | Built-in heat sink | Fanless design | Sensorless Flux Vector Control | V\/f and quadratic V\/f control | Adjustable motor slip compensation | 4 programmable logic inputs | 1 analog input | 1 analog output | 1 logic output | 1 relay output | RS-485 Modbus RTU communication\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eKey Features:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOriginal New Schneider Electric ATV12H037M2 Altivar 12 variable speed drive.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003e0.37 kW \/ 0.55 HP rated motor power for compatible three-phase asynchronous motors.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSingle-phase 200–240 V AC electrical supply with three-phase 200–240 V AC motor output.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eContinuous output current of 2.4 A at the nominal 4 kHz switching frequency.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMaximum transient output current of 3.6 A for 60 seconds.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIntegrated EMC filter for improved electromagnetic compatibility in industrial installations.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBuilt-in heat sink with fanless construction.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIP20 enclosure protection for installation inside suitable electrical cabinets.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSensorless Flux Vector Control supports motor speed regulation without an external speed encoder.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSupports linear V\/f and quadratic V\/f control profiles for different motor-load characteristics.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAdjustable switching frequency from 2 to 16 kHz, subject to applicable derating requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAdjustable acceleration and deceleration ramps from 0 to 999.9 seconds, with linear, S-curve, and U-curve profiles.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFour programmable logic inputs support external motor-control commands.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOne configurable analog input supports 0–10 V, 0–5 V, or 0–20 mA reference signals.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOne configurable analog output supports 0–10 V or 0–20 mA monitoring signals.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOne logic output and one changeover relay output provide flexible control and monitoring interfaces.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBuilt-in RS-485 interface with RJ45 connector supports Modbus RTU communication.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDC injection braking provides motor stopping functionality without requiring an external braking resistor.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAdjustable motor slip compensation supports improved motor speed regulation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIntegrated motor thermal protection uses continuous I²t calculation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCompact M2-frame design is suitable for space-constrained industrial machinery installations.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eApplications:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSmall industrial machinery and automated equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eConveyor systems and material handling machinery.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSmall pumps and water circulation systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eVentilation fans and air-handling equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePackaging and processing machinery.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSmall mixers and production equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eTextile machinery and commercial equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMachine tools and workshop machinery.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePLC-controlled machines using Modbus RTU communication.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSimple automation systems requiring single-phase power supply and three-phase motor control.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eApplications requiring adjustable acceleration, deceleration, and motor speed regulation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eTechnical Specifications:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eAttribute\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCatalog Number\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eATV12H037M2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type Designation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAltivar 12 Variable Speed Drive\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Family\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSchneider Electric Altivar 12\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Category\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVariable Frequency Drive (VFD)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCompact Variable Speed Drive\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Specific Application\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSimple Machines\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAssembly Style\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWith Heat Sink\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Mode\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCabinet Mount\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Motor Power\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.37 kW \/ 0.55 HP\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSupply Phase\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSingle-phase\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e200–240 V AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Voltage Tolerance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-15% \/ +10%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Frequency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50\/60 Hz ±5%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLine Current at 200 V\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5.9 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLine Current at 240 V\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.9 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProspective Line Short-Circuit Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≤1 kA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Phase\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eThree-phase\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e200–240 V AC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eContinuous Output Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.4 A at 4 kHz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum Transient Output Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.6 A for 60 seconds\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Frequency Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5–400 Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSpeed Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1:20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMotor Control\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSensorless Flux Vector \/ V\/f\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAsynchronous Motor Control Profiles\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLinear V\/f \/ Quadratic V\/f\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTransient Over-Torque\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e150–170% of nominal motor torque, depending on motor and drive rating\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNominal Switching Frequency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 kHz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAdjustable Switching Frequency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2–16 kHz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSwitching Frequency with Derating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4–16 kHz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEMC Filter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIntegrated\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEMC Emission Category\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eC1 \/ C2, depending on installation conditions\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBuilt-in Fan\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot Included\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCooling Method\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHeat Sink\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBraking Function\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDC Injection Braking\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBraking Torque Without External Resistor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 70% of nominal motor torque\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMotor Slip Compensation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePreset \/ Adjustable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEnclosure Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20, subject to the specified protective-cover configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Frame\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eM2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Position\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVertical ±10°\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHousing Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePlastic\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAnalog Inputs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAnalog Input Terminal\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAI1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAnalog Input Signals\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0–10 V \/ 0–5 V \/ 0–20 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAnalog Input Impedance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30 kΩ (Voltage) \/ 250 Ω (Current)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDigital Inputs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 programmable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDigital Input Terminals\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLI1, LI2, LI3, LI4\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDigital Input Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDigital Input Logic\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePositive \/ Negative Logic\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDigital Outputs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDigital Output Configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 Logic Output + 1 Relay Output\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLogic Output Terminals\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLO+ \/ LO-\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAnalog Outputs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 programmable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAnalog Output Terminal\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAO1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAnalog Output Signals\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0–10 V \/ 0–20 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAnalog Output Resolution\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 bits\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRelay Outputs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 changeover relay\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRelay Terminals\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eR1A \/ R1B \/ R1C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMinimum Relay Switching Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 mA at 24 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum Relay Rating – Resistive\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3 A at 250 V AC \/ 4 A at 30 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum Relay Rating – Inductive\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 A at 250 V AC \/ 2 A at 30 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCommunication Interface\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTwo-wire RS-485\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCommunication Connector\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 × RJ45\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBuilt-in Communication Protocol\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModbus RTU\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModbus Transmission Rate\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4,800 \/ 9,600 \/ 19,200 \/ 38,400 bit\/s\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModbus Address Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1–247\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInternal Logic Supply\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 V DC, 100 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInternal Potentiometer Reference Supply\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 V DC, 10 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAcceleration \/ Deceleration Ramps\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0–999.9 seconds\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRamp Profiles\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLinear \/ S-Curve \/ U-Curve\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDC Injection Braking Duration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.1–30 seconds\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMotor Thermal Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eContinuous I²t Calculation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAdditional Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSupply Overvoltage, Undervoltage, Output Overcurrent, Motor Short-Circuit and Overheating Protection\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrical Connection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.5 mm² \/ AWG 12\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTerminal Tightening Torque\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.8 N·m\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions (W × H × D)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e72 × 143 × 121.2 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNet Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eApproximately 0.7 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEAN \/ GTIN\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3606480071058\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-10 to +40°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature with Derating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e+40 to +60°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCurrent Derating Above 40°C\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.2% per °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStorage Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-25 to +70°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum Relative Humidity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5–95%, non-condensing\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum Altitude Without Derating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1,000 m\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMaximum Altitude With Derating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2,000 m, subject to 1% current derating per 100 m above 1,000 m\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePollution Degree\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVibration Resistance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIEC 60068-2-6\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShock Resistance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15 gn, IEC 60068-2-27\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEMC Standards\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIEC 61800-3, IEC 61000-4 Series\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrical Safety Standard\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIEC 61800-5-1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCertifications\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCE, UL, CSA, C-Tick, GOST, NOM\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eSystem Compatibility:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDesigned for single-phase 200–240 V AC industrial electrical supply systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eProvides three-phase variable-frequency output for compatible three-phase 200–240 V AC asynchronous motors.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSuitable for motor applications rated up to 0.37 kW \/ 0.55 HP.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eContinuous motor output current must remain within the rated 2.4 A at the nominal 4 kHz switching frequency.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSensorless Flux Vector Control supports motor speed regulation without an external speed encoder.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLinear V\/f and quadratic V\/f control modes provide alternative motor-control configurations.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFour programmable logic inputs support external forward, reverse, stop, and other configured motor-control commands.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOne analog input accepts 0–10 V, 0–5 V, or 0–20 mA reference signals.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOne programmable analog output supports 0–10 V or 0–20 mA external monitoring.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOne logic output supports external status and control signaling.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOne changeover relay output provides a compatible interface for external equipment control and status monitoring.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBuilt-in RS-485 communication supports Modbus RTU integration with compatible PLCs and industrial automation controllers.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eModbus RTU supports configurable communication speeds and device addressing.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eAdjustable motor slip compensation supports improved speed regulation under changing loads.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDC injection braking provides a motor-stopping function without requiring an external braking resistor.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eThe integrated EMC filter supports specified C1 or C2 conducted-emission performance depending on switching frequency, shielded motor-cable length, and installation conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFor installations requiring enhanced EMC conformity, the optional VW3A9523 EMC conformity kit provides an EMC plate, clamps, and mounting accessories.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eThe optional VW3A9804 mounting plate supports installation on a 35 mm symmetrical DIN rail.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIP20 enclosure requires installation inside a suitable electrical control cabinet.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOperating temperatures above +40°C require current derating according to Schneider Electric specifications.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eConfirm motor nameplate voltage, motor current, single-phase supply capacity, control wiring, Modbus settings, EMC requirements, and installation clearances before commissioning or replacement.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eRelated Products:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-spread=\"false\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eATV12H018M2 – Schneider Electric Altivar 12 0.18 kW 200–240 V Single-Phase Variable Speed Drive\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eATV12H055M2 – Schneider Electric Altivar 12 0.55 kW 200–240 V Single-Phase Variable Speed Drive\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eATV12H075M2 – Schneider Electric Altivar 12 0.75 kW 200–240 V Single-Phase Variable Speed Drive\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eATV12H037M3 – Schneider Electric Altivar 12 0.37 kW 200–240 V Three-Phase Variable Speed Drive\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eATV320U04M2C – Schneider Electric Altivar Machine ATV320 0.37 kW 200–240 V Compact Drive\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eVW3A9804 – Schneider Electric Altivar DIN-Rail Mounting Plate for M2 Frame\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eVW3A9523 – Schneider Electric Altivar EMC Conformity Kit\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eVW3A9317 – Schneider Electric Altivar +15 V \/ +24 V Voltage Converter\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003ePLC ERA is an independent industrial automation distributor supplying genuine Original New products through established global supply channels. All products are factory sealed when applicable and undergo quality inspection prior to shipment. Schneider Electric and Altivar are registered trademarks of Schneider Electric SE.\u003c\/span\u003e\u003c\/p\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":68178162123071,"sku":"ATV12H037M2","price":96.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0872\/9477\/1519\/files\/schneider-electric-atv12h037m2-altivar-12-0-37kw-single-phase-variable-speed-drive-original-new.png?v=1795165776","url":"https:\/\/plcera.com\/ar\/products\/atv12h037m2-schneider-electric-altivar-12-0-37kw-variable-speed-drive","provider":"PLC ERA","version":"1.0","type":"link"}