{"title":"Relé de seguridad\/protección","description":"\u003cdiv class=\"text-base my-auto mx-auto [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\" tabindex=\"-1\"\u003e\n\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"3c93bb6c-da8a-470d-9e81-328c237a257a\" dir=\"auto\" data-message-model-slug=\"gpt-5-mini\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal [.text-message+\u0026amp;]:mt-1\"\u003e\n\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\n\u003cdiv class=\"markdown prose dark:prose-invert w-full wrap-break-word light markdown-new-styling\"\u003e\n\n\u003cp data-start=\"0\" data-end=\"224\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e La serie de relés de seguridad\/protección supervisa y controla circuitos críticos, proporcionando detección de fallas, protección contra sobrecargas y parada de emergencia para garantizar la seguridad del personal y la protección de los equipos en sistemas industriales. 🛡️⚡ \u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv class=\"z-0 flex min-h-[46px] justify-start\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\n\u003c\/div\u003e","products":[{"product_id":"schneider-electric-xpsac5121-emergency-stop-module","title":"Módulo de parada de emergencia XPSAC5121 de Schneider Electric: control de seguridad confiable","description":"\u003cp\u003e El módulo de parada de emergencia XPSAC5121 de Schneider Electric garantiza una mayor seguridad para los sistemas industriales. Diseñado para cumplir con los más altos estándares de seguridad, proporciona un control y una supervisión fiables de las funciones de parada de emergencia. Gracias a su compatibilidad con 24 V CA\/CC, este módulo es ideal para proteger al personal y a los equipos en entornos de automatización exigentes.\u003c\/p\u003e\n\n\u003ch3\u003e Características principales\u003c\/h3\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e Monitoreo de paradas de emergencia para sistemas de seguridad industrial\u003c\/li\u003e\n\n\u003cli\u003e Compatible con fuente de alimentación de 24 V CA\/CC\u003c\/li\u003e\n\n\u003cli\u003e Diseño compacto para una fácil integración en paneles de control.\u003c\/li\u003e\n\n\u003cli\u003e Cumple con los estándares internacionales de seguridad en cuanto a confiabilidad.\u003c\/li\u003e\n\n\u003cli\u003e Garantiza una respuesta rápida ante situaciones de emergencia.\u003c\/li\u003e\n\n\u003cli\u003e Original a estrenar, dentro del periodo de garantía.\u003c\/li\u003e\n\n\u003cli\u003e Garantía de satisfacción del 100%\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":50217492054335,"sku":"XPSAC5121","price":118.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0872\/9477\/1519\/files\/xpsac5121-front.jpg?v=1778479558"},{"product_id":"sick-rly3-ossd200-safety-relay-rely-series-1085344","title":"Relé de seguridad SICK RLY3-OSSD200 Serie ReLy 1085344","description":"\u003cp data-start=\"203\" data-end=\"540\"\u003eEl SICK RLY3-OSSD200 (1085344) es un módulo de relé de seguridad de la serie ReLy diseñado para la conmutación segura de señales OSSD. Ideal para su uso en aplicaciones de seguridad hasta PLe\/SIL3, garantiza el aislamiento y la monitorización fiables de señales relacionadas con la seguridad procedentes de dispositivos como barreras fotoeléctricas y escáneres en entornos industriales.\u003c\/p\u003e\n\n\u003cp data-start=\"542\" data-end=\"884\"\u003e \u003cstrong data-start=\"542\" data-end=\"558\"\u003eCaracterísticas principales\u003c\/strong\u003e\u003cbr data-start=\"558\" data-end=\"561\"\u003e ▪ Diseñado para la conmutación segura de señales OSSD\u003cbr data-start=\"602\" data-end=\"605\"\u003e ▪ Adecuado para aplicaciones de seguridad PLe\/SIL3\u003cbr data-start=\"648\" data-end=\"651\"\u003e ▪ 3 salidas de seguridad normalmente abiertas (NO) + 1 salida de señal normalmente cerrada (NC)\u003cbr data-start=\"693\" data-end=\"696\"\u003e ▪ Carcasa compacta para carril DIN para una fácil instalación\u003cbr data-start=\"744\" data-end=\"747\"\u003e ▪ Tensión de funcionamiento de 24 V CC con bajo consumo de energía\u003cbr data-start=\"801\" data-end=\"804\"\u003e ▪ Producto original, completamente nuevo y dentro del período de garantía.\u003cbr data-start=\"852\" data-end=\"855\"\u003e ▪ Garantía de satisfacción del 100%\u003c\/p\u003e","brand":"SICK","offers":[{"title":"Default Title","offer_id":50907549630783,"sku":"RLY3-OSSD200\/1085344","price":135.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0872\/9477\/1519\/files\/rly3-ossd200-1085344-front.jpg?v=1778642311"},{"product_id":"siemens-sirius-safety-relay-3sk1111-1ab30-24v-ac-dc-3no-1nc","title":"Relé de seguridad Siemens SIRIUS 3SK1111-1AB30 24V AC\/DC 3NA 1NC","description":"\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eDescripción general\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eEl relé de seguridad Siemens SIRIUS (3SK1111-1AB30) es una unidad básica diseñada para aplicaciones relacionadas con la seguridad en la automatización industrial. Cuenta con 3 circuitos de habilitación (contactos NA) y 1 circuito de señalización (contacto NC), lo que proporciona una conmutación fiable para sistemas de parada de emergencia, puertas de seguridad y cortinas de luz. Funciona con una fuente de alimentación de 24 V CA\/CC con terminales de tornillo para un cableado seguro, este relé de seguridad cumple con las normas EN ISO 13849-1 e IEC 61508, y admite niveles de integridad de seguridad de hasta PL e \/ SIL 3 cuando se utiliza en arquitecturas de seguridad adecuadas.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eCaracterísticas principales\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e3 circuitos de habilitación\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – 3 contactos NA para conmutación de salida de seguridad.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e1 circuito de señalización\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – 1 contacto NC para retroalimentación de diagnóstico.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eFuente de alimentación amplia\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – 24 V CA\/CC para una instalación flexible.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eTerminales de tornillo\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Conexión de cableado segura y fiable.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eDiseño compacto\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Carcasa que ahorra espacio para la instalación en armarios de control.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eCumplimiento de seguridad\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Adecuado para aplicaciones de seguridad PL e \/ SIL 3.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eProducto original nuevo, dentro del período de garantía\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Producto Siemens genuino, completamente nuevo en embalaje sellado, cubierto por la garantía del fabricante.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eGarantía de satisfacción del 100 %\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Su compra está protegida por nuestra garantía de satisfacción; devuélvalo o cámbielo si no está completamente satisfecho.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eEspecificaciones técnicas\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eTipo de producto: Relé de seguridad (unidad básica)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eModelo: 3SK1111-1AB30\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eSerie: SIRIUS\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eCircuitos de habilitación: 3 contactos NA\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eCircuito de señalización: 1 contacto NC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eFuente de alimentación: 24 V CA\/CC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eConexión: Terminales de tornillo\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eNivel de seguridad: Hasta PL e \/ SIL 3 (según la aplicación)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eNormas: EN ISO 13849-1, IEC 61508\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eAplicaciones\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eIdeal para circuitos de parada de emergencia, supervisión de puertas de seguridad, evaluación de cortinas de luz y otras tareas de control relacionadas con la seguridad en la automatización de fábricas, la construcción de máquinas y las industrias de procesos.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eEl paquete incluye\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003e1 relé de seguridad SIRIUS (3SK1111-1AB30)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eDocumentación y conectores (si corresponde)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SIEMENS","offers":[{"title":"Default Title","offer_id":52487886405951,"sku":"3SK1111-1AB30","price":150.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0872\/9477\/1519\/files\/siemens-sirius-safety-relay-3sk1111-1ab30-24v-acdc-3no-1nc-4896934.jpg?v=1774051027"},{"product_id":"ifm-g1501s-safety-relay-24v-2no-6a-pl-e-sil3","title":"IFM G1501S Safety Relay 24V DC 2NO 6A PL e SIL3 DIN Rail","description":"\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eOverview\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eThe IFM G1501S is a high-performance safety relay (safety switch gear) designed for fail-safe monitoring of safety circuits in industrial automation applications. As a redundant system, this safety relay is suited for fail-safe sensor\/switch monitoring (PNP and clocked types), two-hand control (electronic and mechanical switches), and simultaneity monitoring\u003c\/span\u003e\u003ca href=\"https:\/\/www.manualzz.com\/doc\/o\/3qxxk\/ifm-electronic-efectorno-g1501s-safety-relay-original-ope...-8%EF%BF%BD3--two-hand-control-using-electronic-sensors-switches#page27\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e. It meets the requirements of EN ISO 13849-1: 2008 category 4 PL e, SIL 3 (IEC 61508), and type IIIC (EN 574)\u003c\/span\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/2530975\/Ifm-Electronic-G1501s.html?page=45#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e. The relay provides 2 safety-related NO contacts (floating contacts) and 1 signal output (positive switching). Signal output is via potential-free relay contacts, with cross-monitoring and possible simultaneity monitoring\u003c\/span\u003e\u003ca href=\"https:\/\/datasheets.globalspec.com\/ds\/ifm-electronic\/g1501s\/b9bdf21e-9f17-4b6f-96f5-01fe61e1926a\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e. The G1501S enables connection of mechanical safety switches and electronic fail-safe sensors, and serves as a switching device for two-hand control with mechanical or electronic switches. Monitored or automatic start is selectable, providing flexibility for various safety applications\u003c\/span\u003e\u003ca href=\"https:\/\/datasheets.globalspec.com\/ds\/ifm-electronic\/g1501s\/b9bdf21e-9f17-4b6f-96f5-01fe61e1926a\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eOriginal brand new, within warranty period\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Factory‑sealed, genuine IFM component with full manufacturer warranty.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e100% Satisfaction Guarantee\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Risk‑free purchase; if you are not completely satisfied, we will replace or refund.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eCertified machine safety – PL e \/ SIL 3\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Meets EN ISO 13849-1: 2008 category 4 PL e, SIL 3 (IEC 61508), and type IIIC (EN 574) requirements, ensuring the highest levels of safety integrity for critical machine protection applications\u003c\/span\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/2530975\/Ifm-Electronic-G1501s.html?page=45#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eRedundant system design\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Redundant internal architecture provides defined behaviour under fault conditions, ensuring a safe state is maintained when output contacts are open. Tested and certified by TÜV-Nord\u003c\/span\u003e\u003ca href=\"https:\/\/manualzz.com\/doc\/o\/21eoq6\/ifm-g1501s-safety-relay-operating-instructions-monitoring#page31\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eVersatile application compatibility\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Suitable as safety relay for fail-safe sensors\/switches with 2 PNP outputs, clocked fail-safe sensors, mechanical switches, and 2-channel fail-safe sensors\/switches with contact output\u003c\/span\u003e\u003ca href=\"https:\/\/manualzz.com\/doc\/o\/3qxxc\/ifm-electronic-efectorno-g1501s-safety-relay-original-ope...-8%EF%BF%BD1--safety-relay-for-fail-safe-sensors-switches-with-2-p...\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eCross-monitoring and simultaneity monitoring\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Built-in cross-monitoring detects wiring faults between channels, while simultaneity monitoring ensures proper synchronisation of two-hand control inputs for safe operation\u003c\/span\u003e\u003ca href=\"https:\/\/datasheets.globalspec.com\/ds\/ifm-electronic\/g1501s\/b9bdf21e-9f17-4b6f-96f5-01fe61e1926a\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eMonitored or automatic start selectable\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Configurable start behaviour (monitored start requiring feedback loop, or automatic start) provides flexibility for different safety circuit architectures and machine reset requirements\u003c\/span\u003e\u003ca href=\"https:\/\/datasheets.globalspec.com\/ds\/ifm-electronic\/g1501s\/b9bdf21e-9f17-4b6f-96f5-01fe61e1926a\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e2 safety-related NO contacts (floating) + 1 signal output\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Two normally open safety contacts (6A, 250V AC \/ 24V DC) for switching safety loads, plus one positive-switching signal output for status indication back to the PLC\u003c\/span\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/2530975\/Ifm-Electronic-G1501s.html?page=45#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e24V DC operation with wide tolerance\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Operating voltage 24V DC (19.2…30V DC) including 5% residual ripple; current consumption less than 200mA. Contacts must be protected by fuses with nominal current \u0026lt;3.6A\u003c\/span\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/2530975\/Ifm-Electronic-G1501s.html?page=45#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eWide ambient temperature range (-25…55°C)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Operates reliably in ambient temperatures from -25°C to 55°C (inside switch cabinet) with IP20 protection rating, suitable for demanding industrial environments\u003c\/span\u003e\u003ca href=\"http:\/\/www.qiantuomy.com\/pdshowtwo\/productshow_21273714.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eHigh reliability with PFHd \u0026lt; 2.2E-09\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Probability of dangerous failure per hour (PFHd) is less than 2.2E-09, ensuring long-term safety integrity with a mission time (TM) of ≤ 175,200 hours (~20 years)\u003c\/span\u003e\u003ca href=\"http:\/\/www.qiantuomy.com\/pdshowtwo\/productshow_2061479360.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"http:\/\/www.qiantuomy.com\/pdshowtwo\/productshow_21273714.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"ds-scroll-area ds-scroll-area--show-on-focus-within _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eParameter\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eValue\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIFM Electronic\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eType \/ Part No.\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eG1501S\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFull Model Description\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSafety switch gear \/ Safety relay\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSafety relay (redundant system)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSafety certifications\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEN ISO 13849-1: 2008 category 4 PL e; SIL 3 (IEC 61508); type IIIC (EN 574)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrical design\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRelay\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 V DC (19.2…30 V DC) incl. 5% residual ripple\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCurrent consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt; 200 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput function\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 safety-related NO contacts (floating contacts); 1 signal output (positive switching)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eContact rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 A, 250 V AC \/ 24 V DC (min. 6 mA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShort-circuit protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eContacts to be protected by fuses with nominal current \u0026lt; 3.6 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput characteristics (S34, S43)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\"1\": \u0026gt; 11 V, 6 mA; \"0\": \u0026lt; 5 V, \u0026lt; 500 μA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower-on delay time\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 s\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eResponse time\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt; 200 ms (typical for safety relay category)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAmbient temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-25…55 °C (inside switch cabinet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStorage temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-25…70 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProtection rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHousing material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePA (polyamide)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrical connection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePhoenix Contact MSTBO Combicon connector with screw terminals (supplied)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDIN rail mounting\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions (approx.)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 mm × 75 mm × 30 mm (typical for DIN rail safety relay)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eGross weight (incl. packaging)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e337.7 g\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSafety reliability PFHd\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt; 2.2E-09 (1\/h)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMission time (TM)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≤ 175,200 hours (~20 years)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTÜV certification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTÜV-Nord certified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ecULus approval\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUL 508 certification for general applications (UL has not evaluated safety function)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCertifications\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCE, cULus (UL 508), TÜV-Nord\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRoHS compliant\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCountry of origin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGermany (DE)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eE-stop and safety gate monitoring\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Connection of emergency stop pushbuttons and interlock safety switches to safety circuits requiring PL e \/ SIL 3 performance.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eFail-safe sensor monitoring (PNP and clocked types)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Safe evaluation of 2-channel PNP fail-safe inductive sensors, light barriers, light curtains (ESPE to EN 61496-1), and laser scanners\u003c\/span\u003e\u003ca href=\"https:\/\/manualzz.com\/doc\/o\/3qxxc\/ifm-electronic-efectorno-g1501s-safety-relay-original-ope...-8%EF%BF%BD1--safety-relay-for-fail-safe-sensors-switches-with-2-p...\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eTwo-hand control\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Switching device for two-hand control using mechanical or electronic switches, meeting EN 574 type IIIC requirements for operator safety on presses and dangerous machinery\u003c\/span\u003e\u003ca href=\"https:\/\/datasheets.globalspec.com\/ds\/ifm-electronic\/g1501s\/b9bdf21e-9f17-4b6f-96f5-01fe61e1926a\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/manualzz.com\/doc\/o\/21eoq6\/ifm-g1501s-safety-relay-operating-instructions-monitoring#page31\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eMechanical safety switches\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Monitoring of mechanical fail-safe switches with contact outputs, including 2-channel evaluation with simultaneity monitoring\u003c\/span\u003e\u003ca href=\"https:\/\/manualzz.com\/doc\/o\/21eoq6\/ifm-g1501s-safety-relay-operating-instructions-monitoring#page31\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eMachinery safety circuits\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Integration into safety loops for conveyors, packaging machinery, robotics, and automated production lines.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eHazardous area protection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Safety applications requiring the highest performance level (PL e) and safety integrity level (SIL 3).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003ePackage Includes\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003e1 × IFM G1501S safety relay (safety switch gear)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003ePhoenix Contact MSTBO Combicon connector with screw terminals (supplied)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eInstruction manual \/ operating instructions\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cblockquote\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eℹ️ \u003c\/span\u003e\u003cem\u003e\u003cspan\u003eMounting accessories for DIN rail included. UL has not evaluated the safety function; certification is for general applications per UL 508.\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e","brand":"IFM","offers":[{"title":"Default Title","offer_id":52813128794431,"sku":"G1501S","price":268.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0872\/9477\/1519\/files\/ifm-g1501s-safety-relay-24v-dc-2no-6a-pl-e-sil3-din-rail-7095713.jpg?v=1776699848"}],"url":"https:\/\/plcera.com\/es\/collections\/safety-protection-relay.oembed","provider":"PLC ERA","version":"1.0","type":"link"}