IFM
LDL200 Inductive Conductivity Sensor 100-1,000,000 µS/cm G1 Aseptoflex | IFM
LDL200 Inductive Conductivity Sensor 100-1,000,000 µS/cm G1 Aseptoflex | IFM
Bajas existencias: quedan 8
No se pudo cargar la disponibilidad de retiro
The Original New IFM LDL200 Inductive Conductivity Sensor is a high-performance hygienic sensor designed for precise measurement of conductivity and temperature in conductive liquids. Part of the LDL2xx family, this sensor is specifically engineered for CIP (Clean-in-Place) monitoring in the food and beverage industry, enabling detection of cleaning agent concentration, rinse water contamination, and product residue validation. Featuring an inductive measuring principle, the LDL200 operates without electrodes, eliminating polarization effects and scaling issues common with conductive sensors. The fully welded stainless steel housing with G1 Aseptoflex Vario process connection and IP68/IP69K protection ensures reliable operation in harsh sanitary environments. IO-Link communication provides loss‑free digital transmission of conductivity and temperature values, enabling real‑time process optimization and significant reductions in cleaning agent usage, energy consumption, and water waste.
Core Engineering Highlights:
100–1,000,000 µS/cm measuring range | Inductive (toroidal) measuring principle | 4‑20 mA analog output + IO‑Link | 2% accuracy (MW ± 25 µS/cm) | –25…100°C medium temp (<1h: 150°C) | 16 bar pressure rating | –1000 mbar vacuum resistance | G1 Aseptoflex Vario process connection | IP68 / IP69K protection | M12 connector | 18–30V DC | <100mA current consumption | Gold‑plated contacts | Fully welded stainless steel housing | 5‑year warranty | EHEDG / FDA compliant
Key Features:
-
Original New IFM LDL200 inductive conductivity sensor
-
Inductive (toroidal) measuring principle — no electrodes, no polarization, no scaling
-
Ultra‑wide measuring range: 100 to 1,000,000 µS/cm with selectable resolution (1 µS/cm up to 10,000 µS/cm; 10 µS/cm up to 100,000 µS/cm; 100 µS/cm up to 1,000,000 µS/cm)
-
Integrated temperature measurement: –25°C to +150°C
-
4‑20 mA analog output (scalable) + IO‑Link communication
-
Selectable output function: conductivity or temperature
-
Fully welded stainless steel housing prevents moisture ingress
-
G1 external thread Aseptoflex Vario process connection
-
IP68 (7 days / 3 m water depth) and IP69K protection
-
Pressure rating: 16 bar; vacuum resistance: –1000 mbar
-
Gold‑plated contacts for reliable signal transmission
-
M12 connector for simple, standardised wiring
-
Short‑circuit and reverse polarity protection
-
5‑year warranty from IFM
-
Suitable for media: water, milk, CIP liquids
Applications:
-
CIP (Clean‑in‑Place) monitoring in food and beverage processing
-
Cleaning agent concentration detection during CIP cycles
-
Rinse water contamination monitoring
-
Product residue validation in return lines
-
Process optimisation to reduce chemical, water, and energy consumption
-
Hygienic conductivity measurement in sanitary applications
-
Dairy, beverage, and pharmaceutical process control
-
DN25 and larger pipe sizes without costly pipe extensions
Technical Specifications:
| Attribute | Specification |
|---|---|
| Catalog Number | LDL200 |
| Product Type | Inductive conductivity sensor |
| Measuring Principle | Inductive (toroidal) |
| Measuring Range | 100–1,000,000 µS/cm |
Electrical Data:
| Attribute | Specification |
|---|---|
| Operating Voltage | 18–30V DC |
| Current Consumption | <100 mA |
| Protection Class | III |
| Reverse Polarity Protection | Yes |
| Power‑on Delay | 2 s |
Outputs:
| Attribute | Specification |
|---|---|
| Total Outputs | 1 |
| Output Signal | Analog signal + IO‑Link |
| Analog Current Output | 4–20 mA (scalable) |
| Max. Load | 500 Ω |
| Output Function | Scalable; selectable conductivity / temperature |
Accuracy & Performance:
| Attribute | Specification |
|---|---|
| Accuracy (Conductivity) | 2% MW ± 25 µS/cm |
| Repeatability (Conductivity) | 1% MW ± 25 µS/cm |
| Long‑term Stability | 0.5% MW ± 25 µS/cm |
| Drift | 0.1%/K MW ± 25 µS/cm |
| Resolution (Conductivity) | 1 µS/cm (0–10,000) / 10 µS/cm (10,000–100,000) / 100 µS/cm (100,000–1,000,000) |
| Accuracy (Temperature) | 20–50°C: <±0.2K; –25–150°C: <±1.5K |
| Repeatability (Temperature) | 0.2K |
| Resolution (Temperature) | 0.1K |
| Response Time (Conductivity) | <2 s (T09; damping = 0) |
| Response Time (Temperature) | <40 s (T09) |
Environmental & Physical:
| Attribute | Specification |
|---|---|
| Medium Temperature | –25°C to +100°C (<1h: 150°C) |
| Ambient Temperature | –40°C to +60°C |
| Storage Temperature | –40°C to +85°C |
| Pressure Rating | 16 bar |
| Vacuum Resistance | –1000 mbar |
| Protection Rating | IP68 (7 days / 3 m water depth / 0.3 bar); IP69K |
| Process Connection | G1 external thread Aseptoflex Vario |
| Electrical Connection | M12 connector, gold‑plated contacts |
| Housing Material | Stainless steel (fully welded) |
| MTTF | 129 years |
| Shock Resistance | 50 g (11 ms) |
| Vibration Resistance | 20 g (10–2000 Hz) |
IO‑Link Communication:
| Attribute | Specification |
|---|---|
| Communication Interface | IO‑Link |
| Transmission Type | COM2 (38.4 kBaud) |
| IO‑Link Revision | 1.1 |
| SDCI Standard | IEC 61131‑9 |
| Profiles | Measuring Sensor, Identification and Diagnosis |
| Required Master Port Class | A |
| Process Data (Analog) | 1 |
| Min. Process Cycle Time | 5.6 ms |
| Supported DeviceID | 922 |
System Compatibility:
-
PLCs via 4–20 mA analog input
-
IO‑Link masters for advanced parameterisation and diagnostics
-
M12 A‑coded connection cables (5‑pin)
-
18–30V DC power supplies
-
IFM sanitary fittings and welding adapters
Typical System Architecture:
24V DC Power Supply
↓
LDL200 Inductive Conductivity Sensor (Installed in CIP loop / pipeline)
│
├── 4–20 mA Analog Output → PLC Analog Input (Conductivity / Temperature)
├── IO‑Link → IO‑Link Master (Digital transmission / Diagnostics / Parameter setting)
│
↓
Inductive (Toroidal) Measurement — No Electrodes, No Scaling
↓
CIP System Monitoring (Cleaning agent concentration / Rinse water contamination / Product validation)
Related Products:
-
EVC001 – M12 female cordset, 2m
-
EVC002 – M12 female cordset, 5m
-
EVC003 – M12 female cordset, 10m
-
E30531 – Welding adapter for process sensors (EHEDG / FDA)
-
E30529 – Welding adapter for process sensors (EHEDG / FDA)
-
ZZ1060 – IO‑Link interface (USB)
-
LDL210 – Inductive conductivity sensor, G1 sealing cone version
-
LDL220 – Inductive conductivity sensor, alternative configuration
-
LDL100 – Inductive conductivity sensor, 100–15,000 µS/cm range
PLC ERA is an independent industrial automation distributor supplying 100% genuine Original New products through established global supply channels. IFM is a trademark of ifm electronic gmbh.