{"product_id":"ifm-g1501s-safety-relay-24v-2no-6a-pl-e-sil3","title":"IFM G1501S Safety Relay 24V DC 2NO 6A PL e SIL3 DIN Rail","description":"\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eOverview\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eThe IFM G1501S is a high-performance safety relay (safety switch gear) designed for fail-safe monitoring of safety circuits in industrial automation applications. As a redundant system, this safety relay is suited for fail-safe sensor\/switch monitoring (PNP and clocked types), two-hand control (electronic and mechanical switches), and simultaneity monitoring\u003c\/span\u003e\u003ca href=\"https:\/\/www.manualzz.com\/doc\/o\/3qxxk\/ifm-electronic-efectorno-g1501s-safety-relay-original-ope...-8%EF%BF%BD3--two-hand-control-using-electronic-sensors-switches#page27\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e. It meets the requirements of EN ISO 13849-1: 2008 category 4 PL e, SIL 3 (IEC 61508), and type IIIC (EN 574)\u003c\/span\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/2530975\/Ifm-Electronic-G1501s.html?page=45#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e. The relay provides 2 safety-related NO contacts (floating contacts) and 1 signal output (positive switching). Signal output is via potential-free relay contacts, with cross-monitoring and possible simultaneity monitoring\u003c\/span\u003e\u003ca href=\"https:\/\/datasheets.globalspec.com\/ds\/ifm-electronic\/g1501s\/b9bdf21e-9f17-4b6f-96f5-01fe61e1926a\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e. The G1501S enables connection of mechanical safety switches and electronic fail-safe sensors, and serves as a switching device for two-hand control with mechanical or electronic switches. Monitored or automatic start is selectable, providing flexibility for various safety applications\u003c\/span\u003e\u003ca href=\"https:\/\/datasheets.globalspec.com\/ds\/ifm-electronic\/g1501s\/b9bdf21e-9f17-4b6f-96f5-01fe61e1926a\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eKey Features\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eOriginal brand new, within warranty period\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Factory‑sealed, genuine IFM component with full manufacturer warranty.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e100% Satisfaction Guarantee\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Risk‑free purchase; if you are not completely satisfied, we will replace or refund.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eCertified machine safety – PL e \/ SIL 3\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Meets EN ISO 13849-1: 2008 category 4 PL e, SIL 3 (IEC 61508), and type IIIC (EN 574) requirements, ensuring the highest levels of safety integrity for critical machine protection applications\u003c\/span\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/2530975\/Ifm-Electronic-G1501s.html?page=45#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eRedundant system design\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Redundant internal architecture provides defined behaviour under fault conditions, ensuring a safe state is maintained when output contacts are open. Tested and certified by TÜV-Nord\u003c\/span\u003e\u003ca href=\"https:\/\/manualzz.com\/doc\/o\/21eoq6\/ifm-g1501s-safety-relay-operating-instructions-monitoring#page31\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eVersatile application compatibility\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Suitable as safety relay for fail-safe sensors\/switches with 2 PNP outputs, clocked fail-safe sensors, mechanical switches, and 2-channel fail-safe sensors\/switches with contact output\u003c\/span\u003e\u003ca href=\"https:\/\/manualzz.com\/doc\/o\/3qxxc\/ifm-electronic-efectorno-g1501s-safety-relay-original-ope...-8%EF%BF%BD1--safety-relay-for-fail-safe-sensors-switches-with-2-p...\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eCross-monitoring and simultaneity monitoring\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Built-in cross-monitoring detects wiring faults between channels, while simultaneity monitoring ensures proper synchronisation of two-hand control inputs for safe operation\u003c\/span\u003e\u003ca href=\"https:\/\/datasheets.globalspec.com\/ds\/ifm-electronic\/g1501s\/b9bdf21e-9f17-4b6f-96f5-01fe61e1926a\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eMonitored or automatic start selectable\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Configurable start behaviour (monitored start requiring feedback loop, or automatic start) provides flexibility for different safety circuit architectures and machine reset requirements\u003c\/span\u003e\u003ca href=\"https:\/\/datasheets.globalspec.com\/ds\/ifm-electronic\/g1501s\/b9bdf21e-9f17-4b6f-96f5-01fe61e1926a\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e2 safety-related NO contacts (floating) + 1 signal output\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Two normally open safety contacts (6A, 250V AC \/ 24V DC) for switching safety loads, plus one positive-switching signal output for status indication back to the PLC\u003c\/span\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/2530975\/Ifm-Electronic-G1501s.html?page=45#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e24V DC operation with wide tolerance\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Operating voltage 24V DC (19.2…30V DC) including 5% residual ripple; current consumption less than 200mA. Contacts must be protected by fuses with nominal current \u0026lt;3.6A\u003c\/span\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/2530975\/Ifm-Electronic-G1501s.html?page=45#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eWide ambient temperature range (-25…55°C)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Operates reliably in ambient temperatures from -25°C to 55°C (inside switch cabinet) with IP20 protection rating, suitable for demanding industrial environments\u003c\/span\u003e\u003ca href=\"http:\/\/www.qiantuomy.com\/pdshowtwo\/productshow_21273714.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eHigh reliability with PFHd \u0026lt; 2.2E-09\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Probability of dangerous failure per hour (PFHd) is less than 2.2E-09, ensuring long-term safety integrity with a mission time (TM) of ≤ 175,200 hours (~20 years)\u003c\/span\u003e\u003ca href=\"http:\/\/www.qiantuomy.com\/pdshowtwo\/productshow_2061479360.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"http:\/\/www.qiantuomy.com\/pdshowtwo\/productshow_21273714.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eTechnical Specifications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"ds-scroll-area ds-scroll-area--show-on-focus-within _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eParameter\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eValue\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eManufacturer\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIFM Electronic\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eType \/ Part No.\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eG1501S\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFull Model Description\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSafety switch gear \/ Safety relay\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSafety relay (redundant system)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSafety certifications\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEN ISO 13849-1: 2008 category 4 PL e; SIL 3 (IEC 61508); type IIIC (EN 574)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrical design\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRelay\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 V DC (19.2…30 V DC) incl. 5% residual ripple\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCurrent consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt; 200 mA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput function\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 safety-related NO contacts (floating contacts); 1 signal output (positive switching)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eContact rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 A, 250 V AC \/ 24 V DC (min. 6 mA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShort-circuit protection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eContacts to be protected by fuses with nominal current \u0026lt; 3.6 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput characteristics (S34, S43)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\"1\": \u0026gt; 11 V, 6 mA; \"0\": \u0026lt; 5 V, \u0026lt; 500 μA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower-on delay time\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 s\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eResponse time\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt; 200 ms (typical for safety relay category)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAmbient temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-25…55 °C (inside switch cabinet)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStorage temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-25…70 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProtection rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHousing material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePA (polyamide)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectrical connection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePhoenix Contact MSTBO Combicon connector with screw terminals (supplied)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDIN rail mounting\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions (approx.)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 mm × 75 mm × 30 mm (typical for DIN rail safety relay)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eGross weight (incl. packaging)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e337.7 g\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSafety reliability PFHd\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt; 2.2E-09 (1\/h)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMission time (TM)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≤ 175,200 hours (~20 years)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTÜV certification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTÜV-Nord certified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ecULus approval\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUL 508 certification for general applications (UL has not evaluated safety function)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCertifications\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCE, cULus (UL 508), TÜV-Nord\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRoHS compliant\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCountry of origin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eGermany (DE)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eE-stop and safety gate monitoring\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Connection of emergency stop pushbuttons and interlock safety switches to safety circuits requiring PL e \/ SIL 3 performance.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eFail-safe sensor monitoring (PNP and clocked types)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Safe evaluation of 2-channel PNP fail-safe inductive sensors, light barriers, light curtains (ESPE to EN 61496-1), and laser scanners\u003c\/span\u003e\u003ca href=\"https:\/\/manualzz.com\/doc\/o\/3qxxc\/ifm-electronic-efectorno-g1501s-safety-relay-original-ope...-8%EF%BF%BD1--safety-relay-for-fail-safe-sensors-switches-with-2-p...\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eTwo-hand control\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Switching device for two-hand control using mechanical or electronic switches, meeting EN 574 type IIIC requirements for operator safety on presses and dangerous machinery\u003c\/span\u003e\u003ca href=\"https:\/\/datasheets.globalspec.com\/ds\/ifm-electronic\/g1501s\/b9bdf21e-9f17-4b6f-96f5-01fe61e1926a\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/manualzz.com\/doc\/o\/21eoq6\/ifm-g1501s-safety-relay-operating-instructions-monitoring#page31\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eMechanical safety switches\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Monitoring of mechanical fail-safe switches with contact outputs, including 2-channel evaluation with simultaneity monitoring\u003c\/span\u003e\u003ca href=\"https:\/\/manualzz.com\/doc\/o\/21eoq6\/ifm-g1501s-safety-relay-operating-instructions-monitoring#page31\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eMachinery safety circuits\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Integration into safety loops for conveyors, packaging machinery, robotics, and automated production lines.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eHazardous area protection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e – Safety applications requiring the highest performance level (PL e) and safety integrity level (SIL 3).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003ePackage Includes\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003e1 × IFM G1501S safety relay (safety switch gear)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003ePhoenix Contact MSTBO Combicon connector with screw terminals (supplied)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eInstruction manual \/ operating instructions\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cblockquote\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eℹ️ \u003c\/span\u003e\u003cem\u003e\u003cspan\u003eMounting accessories for DIN rail included. UL has not evaluated the safety function; certification is for general applications per UL 508.\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e","brand":"IFM","offers":[{"title":"Default Title","offer_id":52813128794431,"sku":"G1501S","price":268.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0872\/9477\/1519\/files\/ifm-g1501s-safety-relay-24v-dc-2no-6a-pl-e-sil3-din-rail-7095713.jpg?v=1776699848","url":"https:\/\/plcera.com\/products\/ifm-g1501s-safety-relay-24v-2no-6a-pl-e-sil3","provider":"PLC ERA","version":"1.0","type":"link"}