The Original New Danfoss 132F0058 (FC-051P11KT4E20H3BXCXXXSXXX) VLT® Micro Drive FC 51 is an 11 kW (15 HP) three-phase drive for 380–480 V supplies, built for panel builders and machine builders who need compact, dependable motor control at low installation cost. In the M4 frame it delivers 23 A continuous output at 380–440 V and 21 A at 440–480 V, with 150% overload for one minute.

The model code specifies the H3 RFI filter, a built-in brake chopper, coated PCBs and no local control panel, so the drive is normally set up from a PLC, a fieldbus network or an optional LCP 11 / LCP 12 panel. RS-485 communication supports Modbus RTU and the Danfoss FC protocol, the control terminals provide five digital inputs, two analog inputs, one analog output and one relay output, and parameters can be set or backed up from a PC with the VLT Motion Control Tool MCT 10.

Motor control is sensorless vector (VVC+) or V/f, with automatic motor tuning, automatic energy optimisation, flying start, electronic thermal relay and a PI process controller built in. The compact book-style housing allows side-by-side mounting for IP20 units, with at least 100 mm free above and below the drive for cooling airflow. Conformally coated PCBs (IEC 60721-3-3 Class 3C3) provide additional protection for the internal electronics against humidity, corrosive gases and aggressive atmospheres; the enclosure rating remains IP20, so the drive should still be mounted in a suitable cabinet, especially where dust is present.

At 125 × 292 × 241 mm and 6.0 kg, the M4 frame fits where larger drives will not, while the built-in RFI filter limits radio disturbance from motor cables. Note that the H3 filter class is specified with a reduced motor cable length; check the Danfoss cable length table during panel design.

Core engineering highlights: VLT Micro Drive FC 51 | 11 kW / 15 HP | Three-phase 380–480 V AC | 23 A continuous output at 380–440 V, 21 A at 440–480 V | 150% overload for 60 s | IP20 / Chassis, M4 frame | 125 × 292 × 241 mm, 6.0 kg | H3 RFI filter, class A1/B (C1) | Built-in brake chopper | Coated PCB | No LCP included | RS-485 with Modbus RTU and FC protocol | VVC+ sensorless vector and V/f control | PI process controller, AEO and AMT | Estimated power loss 290 W best case / 342 W typical, efficiency 97.8% / 97.4% at rated load | Side-by-side mounting possible, 100 mm clearance above and below | Compact, low-cost general-purpose drive

Key Features

  • Original New Danfoss 132F0058 VLT Micro Drive FC 51 frequency converter.
  • 11 kW / 15 HP rating for three-phase 380–480 V AC supplies.
  • 23 A continuous output current at 380–440 V and 21 A at 440–480 V.
  • 150% overload for 60 seconds (34.5 A / 31.5 A intermittent) for heavy starts.
  • IP20 / Chassis enclosure in the M4 frame, 125 × 292 × 241 mm, 6.0 kg.
  • Built-in H3 RFI filter, class A1/B (C1), reducing radio disturbance from motor cables.
  • Built-in brake chopper for dynamic braking with a suitable external brake resistor.
  • Estimated power loss 290 W best case / 342 W typical at rated load, efficiency 97.8% / 97.4%, supporting cabinet cooling design.
  • Conformally coated PCBs (IEC 60721-3-3 Class 3C3) for protection against humidity, corrosive gases and aggressive atmospheres; enclosure rating remains IP20.
  • Sensorless vector control (VVC+) or V/f, selectable per application.
  • Automatic Motor Tuning (AMT) to match the drive to the connected motor.
  • Automatic Energy Optimizer (AEO) for reduced energy consumption at partial load.
  • Integrated PI process controller for pressure, flow, level or temperature loops.
  • Flying start for catching a spinning motor, and electronic thermal relay (ETR) motor protection.
  • Smart Logic Controller for simple sequence logic without an external PLC.
  • RS-485 port supporting Modbus RTU and Danfoss FC protocol for PLC and SCADA integration.
  • Five digital inputs, two analog inputs, one analog output and one relay output.
  • Side-by-side mounting possible for IP20 units to save panel width, with at least 100 mm clearance above and below for cooling airflow.
  • No local control panel included; LCP 11 or LCP 12 can be added as an accessory.
  • Parameter setting and backup through the optional LCP or the VLT Motion Control Tool MCT 10.
  • Effective heat-sink design that removes heat from the electronics and extends service life.
  • Compact, low-cost general-purpose drive for OEM machines and standard panels.

Applications

  • Conveyors and small material handling equipment.
  • Fans, blowers and centrifugal pumps.
  • Mixers, agitators and small processing machines.
  • Packaging, labeling and filling machines.
  • Woodworking, textile and plastic machinery.
  • Machine tools and auxiliary drives in OEM equipment.
  • Water and wastewater pumps with PI process control.
  • Panels where space, depth and cost are constrained.
  • Machines controlled from a PLC over Modbus RTU.
  • Replacement of existing FC 51 drives in installed machinery.

Technical Specifications

Attribute Specification
Ordering Number 132F0058
Product Type Designation VLT Micro Drive FC 51
Product Family Danfoss VLT Micro Drive
Product Category Drives, Motors & Controls
Product Type Variable Frequency Drive (VFD)
Series FC 51
Full Model Code FC-051P11KT4E20H3BXCXXXSXXX
Rated Output Power 11 kW / 15 HP
Power Rating Code P11K
Number of Phases Three-phase
Supply Voltage 380–480 V AC
Supply Frequency 50/60 Hz
Continuous Output Current 23 A at 380–440 V / 21 A at 440–480 V
Intermittent Output Current 34.5 A at 380–440 V / 31.5 A at 440–480 V
Overload Capability 150% for 60 s
Continuous Input Current 33 A at 380–440 V / 29 A at 440–480 V
Intermittent Input Current 47.5 A at 380–440 V / 41 A at 440–480 V
Estimated Power Loss 290 W best case / 342 W typical at rated load, default switching frequency
Efficiency at Rated Load 97.8% best case / 97.4% typical
Maximum Motor Cable Size 16 mm² / AWG 6
Motor Control Principle VVC+ sensorless vector and V/f (U/f)
Enclosure Rating IP20 / Chassis (E20)
Frame Size M4
Dimensions (W × H × D) 125 × 292 × 241 mm
Mounting Clearance Side-by-side mounting possible for IP20 units; at least 100 mm free above and below for cooling
RFI Filter H3, class A1/B (C1), specified with reduced motor cable length
Brake Chopper Built-in
Local Control Panel Not included; LCP 11 (132B0100) or LCP 12 (132B0101) optional
PCB Protection Coated PCB
Mains Option None
Serial Communication RS-485: Modbus RTU, Danfoss FC protocol
Digital Inputs 5 programmable digital inputs
Analog Inputs 2 (0–10 V; one configurable for 0/4–20 mA)
Analog Outputs 1 (0/4–20 mA)
Relay Outputs 1
Process Controller Integrated PI controller
Ambient Temperature Up to 50 °C ambient with derating; continuous full load at 50 °C reduces drive lifetime
Altitude No derating below 1000 m; reduce output 1% per 100 m above 1000 m
Net Weight 6.0 kg
Gross Weight 6.3 kg
EAN / GTIN 5702427554443
Manufacturer Danfoss
Product Brand VLT

Type Code Decoder

The full model code FC-051P11KT4E20H3BXCXXXSXXX is decoded as follows, so the exact configuration can be confirmed before ordering or replacing a drive.

Code Meaning
FC-051 VLT Micro Drive FC 51 series
P11K 11 kW / 15 HP output rating
T4 Three-phase, 380–480 V AC supply
E20 IP20 / Chassis enclosure
H3 Built-in RFI filter, class A1/B (C1), reduced motor cable length
B Built-in brake chopper
X No local control panel (LCP 11 / LCP 12 optional)
C Coated PCB
X (mains option) No mains option
X (adaptation A) Standard cable entries
X (adaptation B) No additional adaptation
SXXX Latest standard software release

System Compatibility

  • Designed for three-phase 380–480 V AC industrial motor-control systems with standard induction motors.
  • VVC+ sensorless vector or V/f control, selectable to suit the load type.
  • RS-485 port supporting Modbus RTU and Danfoss FC protocol for PLC, HMI and SCADA networks.
  • Five digital inputs, two analog inputs, one analog output and one relay output for stand-alone control.
  • Built-in brake chopper accepts a suitable external Danfoss brake resistor for dynamic braking.
  • H3 RFI filter class is specified with a reduced motor cable length; check the Danfoss cable length table and use screened motor cable for EMC compliance.
  • IP20 units can be mounted side-by-side; keep at least 100 mm free above and below the drive for cooling airflow.
  • Derating applies above 40 °C ambient and above 1000 m installation altitude; the drive is designed for a maximum of 50 °C ambient with reduced load.
  • No local control panel is fitted: add LCP 11 (132B0100), LCP 12 (132B0101) or the LCP remote mounting kit (132B0102) for local operation or panel-door access.
  • Parameter setting and backup through the optional LCP or the VLT Motion Control Tool MCT 10.
  • The FC 51 does not provide a Safe Torque Off function; machine safety must be implemented by external safety devices.
  • Confirm motor current, cable length, brake resistor selection, ambient temperature and fieldbus settings before commissioning.
  • Installation and servicing must follow Danfoss instructions and be performed by qualified personnel.

Related Products

  • 132B0100 – VLT Control Panel LCP 11 without potentiometer, IP20 / front IP54, numerical display with copy function.
  • 132B0101 – VLT Control Panel LCP 12 with potentiometer, IP20 / front IP54.
  • 132B0102 – LCP remote mounting kit with 3 m cable for panel-door installation of LCP 11 or LCP 12.
  • 132B0131 – VLT protection blank cover for drives supplied without an LCP, protecting the panel connector.
  • 132B0120 – NEMA 1 / Type 1 conversion kit for the M4 frame, for enclosure conversion when the drive is installed outside a cabinet (the IP21 / Type 1 kits 132B0108 and 132B0109 are for M1 and M2 frames only).
  • 132B0122 – De-coupling plate kit for M4 and M5 frames, for screened motor cable connection and EMC performance.
  • 136N8935 – VLT Micro Drive FC 51 7.5 kW, IP20, brake chopper, without RFI filter.
  • 132F0017 – VLT Micro Drive FC 51 0.37 kW, IP20, RFI filter, M1 frame.
  • Danfoss VLT brake resistors (MCE 101 range) – external dynamic braking resistors; the correct type must be selected according to braking torque, resistance value, braking power and duty cycle.
  • VLT Midi Drive FC 280 and VLT AutomationDrive FC 302 – higher-performance platforms when the application needs more I/O, fieldbus options or safety functions.

PLC ERA is an independent industrial automation distributor supplying genuine Original New products through established global supply channels. All products are factory sealed when applicable and undergo quality inspection prior to shipment. Danfoss and VLT are registered trademarks of Danfoss A/S.

Nota: Para garantizar que reciba la cotización más competitiva del momento, le recomendamos que se ponga en contacto con nuestro equipo de ventas. Dado que los precios del mercado se actualizan constantemente, le proporcionaremos la información más reciente. Puede completar el formulario de contacto a continuación y esperar a que nuestro servicio de atención al cliente se comunique con usted, usar el chat en línea en la esquina inferior derecha o hacer clic directamente en " Contactar con el servicio de atención al cliente ".