The IFM TA2502 (TA-030CLER12- - /US) is a high-performance RTD temperature transmitter designed for precise temperature measurement in hygienic industrial applications. Featuring a Pt1000 measuring element (Class A to DIN EN 60751) with a measurement range of -50°C to 200°C, this compact transmitter delivers high accuracy across the entire temperature range. The device provides a scalable 4…20 mA analogue output (invertible) and integrated IO-Link V1.1 communication (COM2, 38.4 kBaud) for remote parameterisation, process data readout, and diagnostics.

The hygienic design, with stainless steel (316L/1.4404) wetted parts electropolished to Ra < 0.8 and EHEDG/FDA-compliant materials, meets the strict sanitation requirements of the food and beverage industry. Rated IP67, IP68, and IP69K, the transmitter withstands dust, continuous immersion, and high-pressure, high-temperature washdowns. With a pressure rating of 160 bar (vacuum resistance down to -1000 mbar), response time T09 < 2 seconds, power-on delay of only 2 seconds, and MTTF of 232 years, the TA2502 is built for demanding process applications including food & beverage, pharmaceutical, and chemical industries.

Key Features

  • Original brand new, within warranty period – Factory‑sealed, genuine IFM component with full manufacturer warranty.

  • 100% Satisfaction Guarantee – Risk‑free purchase; if you are not completely satisfied, we will replace or refund.

  • Hygienic design for food and beverage industry – EHEDG/FDA-compliant materials, stainless steel (316L/1.4404) wetted parts electropolished to Ra < 0.8, ensuring cleanability and meeting strict sanitation requirements.

  • High precision across entire temperature measurement range – Pt1000 Class A measuring element (to DIN EN 60751) delivers ±0.3 K + (±0.1% of span) precision with 0.04 K resolution, ensuring accurate temperature monitoring.

  • Scalable 4‑20 mA analogue output with IO‑Link V1.1 – Configurable analogue output (4‑20 mA or 20‑4 mA, invertible) with IO‑Link V1.1 communication (COM2, 38.4 kBaud) enables remote parameterisation, process data readout, and diagnostics.

  • Fast response dynamics and very short power‑on delay time – Response time T09 < 2 s, T05 < 0.5 s, power‑on delay only 2 s, enabling rapid temperature detection for dynamic process control.

  • Robust stainless steel housing with triple IP rating – IP67, IP68, and IP69K protection ratings with stainless steel (316L/1.4404) housing resist dust, continuous immersion, and high‑pressure washdowns.

  • High pressure resistance and wide temperature operation – Pressure rating 160 bar, vacuum resistance -1000 mbar, ambient temperature -25…80 °C (medium: -50…200 °C).

  • Diagnostic output for drift and fault monitoring – Built‑in self-monitoring with diagnostic output for drift and fault detection, ensuring high process safety and reducing unplanned downtime.

  • Free 5‑point calibration certificate included – Includes factory certificate with 5‑point calibration traceable to international standards, ensuring measurement accuracy and compliance.

  • High reliability with MTTF of 232 years – Exceptional mean time to failure ensures long‑term dependable operation, minimising unplanned downtime and maintenance costs.

Technical Specifications



Parameter Value
Manufacturer IFM Electronic
Type / Part No. TA2502
Full Model Code TA-030CLER12- - /US
Product type Temperature transmitter (RTD)
Measuring element 1 x Pt1000 (to DIN EN 60751, Class A)
Measuring range -50…200 °C
Factory setting 0…200 °C
Analogue output 4…20 mA (scalable, invertible)
Analogue output resolution 0.04 K
Precision (analogue output) ±0.3 K + (±0.1% of span)
Response time (T05 / T09) < 0.5 s / < 2 s
Power‑on delay time 2 s
IO-Link version V1.1, COM2 (38.4 kBaud)
Operating voltage 18…32 V DC (Class 2 to cULus)
Current consumption < 50 mA
Max. analogue load 250 Ω (18…19 V) / 300 Ω (19…32 V)
Protection class III
Reverse polarity protection Yes
Short‑circuit / overload protection Yes
Process connection G 1/2 sealing cone
Installation length (EL) 30 mm
Probe diameter 6 mm
Pressure rating 160 bar
Vacuum resistance -1000 mbar
Media Liquids and gases
Ambient temperature -25…80 °C (note derating at medium < 200 °C)
Medium temperature -50…200 °C
Storage temperature -40…100 °C
Enclosure rating IP67; IP68; IP69K
Vibration resistance 10 g (10…2000 Hz) to DIN IEC 68-2-6
Shock resistance 50 g (11 ms) to DIN IEC 68-2-27
EMC compliance DIN EN 61000-6-2, DIN EN 61000-6-3
MTTF 232 years
UL approval K002
Surface characteristics (wetted parts) Ra: < 0.8 (electropolished)
Tightening torque 30…50 Nm
Housing material Stainless steel (1.4404 / 316L); PEI; FKM
Wetted parts material Stainless steel (1.4404 / 316L) electropolished
Electrical connection M12 A‑coded connector, 4‑pin
Net weight 180.5 g (0.1805 kg)
Gross weight (incl. packaging) Approx. 0.20 kg (200 g)
Dimensions Ø 18.7 mm
Pack quantity 1 piece
Certifications CE, cULus, EAC
RoHS compliant Yes
Country of origin United States (US) / Germany (DE)

Applications

  • Food and beverage industry – Temperature monitoring in CIP/SIP washdown environments, pasteurisers, sterilisation tunnels, mixing tanks, and filling lines.

  • Pharmaceutical and biotechnology – Sterile processing equipment, bioreactors, fermentation vessels, and cleanroom applications requiring EHEDG/FDA-compliant sanitary design.

  • Chemical processing – Reaction vessels, heat exchangers, and distillation columns requiring high pressure resistance (160 bar) and wide temperature range (-50…200 °C).

  • Dairy processing – Milk pasteurisation, cheese vats, and yoghurt fermentation monitoring.

  • Brewing and beverage – Mash tuns, fermentation tanks, bright beer tanks, and carbonation vessels.

  • Packaging machinery – Temperature monitoring in hot fillers, seal bars, and shrink tunnels.

  • Process automation – General industrial temperature measurement requiring 4‑20 mA analogue output with IO‑Link diagnostic capabilities.

Package Includes

  • 1 × IFM TA2502 temperature transmitter (TA-030CLER12- - /US)

  • Free 5‑point calibration certificate

  • Instruction manual (available at www.factory-certificate.ifm)

⚠️ *M12 mating connector sold separately. Compatible with EHEDG/FDA-compliant weldable adapters (e.g., IFM E30050 series).*

Nota: Para garantizar que reciba la cotización más competitiva del momento, le recomendamos que se ponga en contacto con nuestro equipo de ventas. Dado que los precios del mercado se actualizan constantemente, le proporcionaremos la información más reciente. Puede completar el formulario de contacto a continuación y esperar a que nuestro servicio de atención al cliente se comunique con usted, usar el chat en línea en la esquina inferior derecha o hacer clic directamente en " Contactar con el servicio de atención al cliente ".