The Original New Danfoss 131H1600 (FC-302P30KT5E20H1XGXXXXSXXXXA0BXCXXXXDX) VLT® AutomationDrive FC 302 is a high-performance frequency converter designed for precise three-phase AC motor control in industrial automation applications. With a rated output of 30 kW (40 HP) under high-overload operation and a 380–500 V AC power supply, this model provides reliable motor control for demanding industrial machinery and production systems.
Designed for both high-overload and normal-overload applications, the FC 302 supports a 30 kW high-overload rating and a 37 kW normal-overload rating. Its high-overload configuration supports 150% overload current for 60 seconds, making it suitable for applications requiring increased starting torque and short-term overload capability.
This specific configuration features an IP20 chassis enclosure, B4 frame, H1 RFI filter (Class A1/B, C1), and an integrated graphical Local Control Panel (LCP 102). It also includes a factory-installed PROFIBUS DP V1 MCA 101 communication option for integration with compatible PLC and industrial control systems.
The 131H1600 is supplied without a built-in brake chopper, with standard Class 3C2 PCB coating, standard cable entries, and no additional mains option. Its type code also specifies no B, C, or D option modules, meaning the MCB 107 24 V DC backup supply is not included.
Combining advanced motor-control capabilities, PROFIBUS communication, integrated operator control, and a compact B4 chassis design, the VLT AutomationDrive FC 302 is a practical solution for industrial machinery, manufacturing lines, and PLC-based automation systems.
Core Engineering Highlights:
VLT AutomationDrive FC 302 frequency converter | 30 kW / 40 HP high-overload rating | 37 kW / 50 HP normal-overload rating | Three-phase 380–500 V AC supply | 150% high-overload current for 60 seconds | IP20 chassis enclosure | B4 frame size | H1 RFI filter, Class A1/B (C1) | Graphical LCP 102 control panel included | Integrated PROFIBUS DP V1 MCA 101 | Standard Class 3C2 PCB coating | No built-in brake chopper | No MCB 107 24 V DC backup option
Key Features:
-
Original New Danfoss 131H1600 VLT AutomationDrive FC 302 frequency converter.
-
30 kW (40 HP) high-overload rated output and 37 kW (50 HP) normal-overload rating.
-
Three-phase 380–500 V AC power supply.
-
High-overload capability of 150% output current for 60 seconds.
-
Continuous output current of 61 A at 380–440 V and 52 A at 441–500 V in high-overload operation.
-
IP20 / chassis enclosure with B4 frame construction.
-
H1 RFI filter, Class A1/B (C1), for electromagnetic interference control.
-
Integrated graphical Local Control Panel LCP 102 for local operation, monitoring, and commissioning.
-
Factory-installed PROFIBUS DP V1 MCA 101 communication option.
-
Built-in DC-link choke for supporting the drive's DC-link arrangement.
-
Standard Class 3C2 PCB coating.
-
No built-in brake chopper.
-
No additional mains option or cable-entry adaptation.
-
No MCB 107 24 V DC backup supply option.
-
Latest released standard software and standard language package.
Applications:
-
Industrial conveyor and material-handling systems.
-
Heavy-duty production and manufacturing machinery.
-
Industrial pumps and high-capacity ventilation systems.
-
Mixers, agitators, and process equipment.
-
Compressors and industrial machinery.
-
Packaging and automated production lines.
-
PLC-based motor-control and process automation systems.
-
PROFIBUS DP industrial communication networks.
-
Industrial applications requiring precise speed and torque regulation.
-
OEM machinery and large-scale automation projects.
Technical Specifications:
|
Attribute |
Specification |
|---|---|
|
Catalog Number |
131H1600 |
|
Complete Type Code |
FC-302P30KT5E20H1XGXXXXSXXXXA0BXCXXXXDX |
|
Product Type Designation |
VLT AutomationDrive FC 302 |
|
Product Family |
Danfoss VLT AutomationDrive |
|
Product Category |
Drives, Motors & Controls |
|
Product Type |
AC Frequency Converter |
|
High-Overload Rated Output |
30 kW / 40 HP |
|
Normal-Overload Rated Output |
37 kW / 50 HP |
|
High-Overload Capacity |
150% for 60 seconds |
|
Normal-Overload Capacity |
110% for 60 seconds |
|
Supply Voltage |
380–500 V AC |
|
Supply Phases |
3-phase |
|
Supply Frequency |
50/60 Hz |
|
Continuous Output Current (HO, 380–440 V) |
61 A |
|
Intermittent Output Current (HO, 380–440 V) |
91.5 A for 60 seconds |
|
Continuous Output Current (HO, 441–500 V) |
52 A |
|
Intermittent Output Current (HO, 441–500 V) |
78 A for 60 seconds |
|
Continuous Output Current (NO, 380–440 V) |
73 A |
|
Intermittent Output Current (NO, 380–440 V) |
80.3 A for 60 seconds |
|
Continuous Output Current (NO, 441–500 V) |
65 A |
|
Intermittent Output Current (NO, 441–500 V) |
71.5 A for 60 seconds |
|
Continuous Input Current (HO, 380–440 V) |
55 A |
|
Continuous Input Current (NO, 380–440 V) |
66 A |
|
Continuous Input Current (HO, 441–500 V) |
47 A |
|
Continuous Input Current (NO, 441–500 V) |
59 A |
|
Continuous KVA (400 V, HO) |
42.3 kVA |
|
Continuous KVA (400 V, NO) |
50.6 kVA |
|
Enclosure Protection |
IP20 / Chassis |
|
Frame Size |
B4 |
|
RFI Filter |
H1 – Class A1/B (C1) |
|
Brake Chopper |
Not Included |
|
Local Control Panel |
Graphical LCP 102 Included |
|
PCB Coating |
Standard Class 3C2 |
|
Mains Option |
None |
|
Cable Entry |
Standard |
|
Adaptation A |
Standard Cable Entries |
|
Adaptation B |
No Adaptation |
|
A Option |
PROFIBUS DP V1 MCA 101 |
|
B Option |
None |
|
C0 Option |
None |
|
C1 Option |
None |
|
C Software Option |
None |
|
D Option |
None – No 24 V DC Backup |
|
Software Release |
Latest Released Standard Software |
|
Software Language |
Standard Language Package |
|
Estimated Power Loss (HO) |
570 W |
|
Estimated Power Loss (NO) |
698 W |
|
Efficiency |
Approximately 98% |
|
Dimensions (H × W × D) |
520 × 230 × 242 mm |
|
Height with Ground Termination Plate for Fieldbus Cables |
595 mm |
|
Maximum Weight |
23.5 kg |
|
Manufacturer |
Danfoss |
|
Product Brand |
VLT |
System Compatibility:
-
Designed for industrial motor-control applications using the Danfoss VLT AutomationDrive FC 302 platform.
-
Compatible with three-phase AC power systems operating within the specified 380–500 V supply range.
-
Suitable for 30 kW high-overload motor applications and 37 kW normal-overload applications, subject to the corresponding output-current ratings.
-
High-overload operation supports 150% output current for 60 seconds, while normal-overload operation supports 110% for 60 seconds.
-
The integrated PROFIBUS DP V1 MCA 101 option supports communication with compatible PROFIBUS DP master controllers and PLC systems.
-
PROFIBUS DP V1 supports cyclic process-data exchange and acyclic parameter access for compatible automation applications.
-
The graphical LCP 102 provides local drive operation, parameter configuration, monitoring, and commissioning functions.
-
Built-in communication protocols include FC Protocol, N2 Metasys, FLN Apogee, and Modbus RTU.
-
The H1 RFI filter corresponds to Class A1/B (C1) under the specified EMC installation conditions.
-
The IP20 B4 chassis is intended for installation inside a suitable electrical control cabinet.
-
The standard Class 3C2 PCB coating is different from the enhanced Class 3C3 coated PCB configuration.
-
No built-in brake chopper is included. Applications requiring dynamic braking must account for this hardware limitation when designing the braking arrangement.
-
No MCB 107 24 V DC backup supply is included. The control section therefore does not have the additional external DC backup feature specified by the D0 option.
-
The drive does not include additional B, C0, C1, C software, or D option modules.
-
The B4 frame has a maximum specified weight of 23.5 kg. Allow for the additional fieldbus cable termination plate when planning installation clearance.
-
Verify motor rated current, supply voltage, overload requirements, PROFIBUS configuration, EMC conditions, and braking requirements before selecting this drive as a replacement.
-
Confirm the complete type code and installed MCA 101 communication option when matching an existing FC 302 installation.
Related Products:
-
130B1100 – Danfoss VLT PROFIBUS DP V1 MCA 101 Communication Option Card
-
130B1107 – Danfoss VLT Graphical Local Control Panel LCP 102
-
134B5223 – Danfoss LCP Remote Mounting Kit with 3 m Cable
-
134B5224 – Danfoss LCP Remote Mounting Kit with 5 m Cable
-
134B5225 – Danfoss LCP Remote Mounting Kit with 10 m Cable
PLC ERA is an independent industrial automation distributor supplying genuine Original New products through established global supply channels. All products are factory sealed when applicable and undergo quality inspection prior to shipment. Danfoss and VLT are trademarks of Danfoss A/S.
Shipping Details & Duties: Please note that we ship directly from Shenzhen, China, under DAP (Delivered at Place) terms. This means buyers are fully responsible for paying all local import duties, taxes, and customs clearance fees upon arrival. If a package is refused or abandoned due to unpaid customs duties, taxes, or remote surcharges, the buyer will be held responsible for the original shipping fee, all return shipping costs, and any associated losses.
Share