Danfoss
132F0030 VLT Micro Drive FC 51 7.5 kW 380–480 V Frequency Converter | Danfoss
132F0030 VLT Micro Drive FC 51 7.5 kW 380–480 V Frequency Converter | Danfoss
20 in stock
Couldn't load pickup availability
The Original New Danfoss 132F0030 (FC-051P7K5T4E20H3BXCXXXSXXX) VLT® Micro Drive FC 51 is a compact, general-purpose variable frequency drive designed for reliable speed control of three-phase AC motors in industrial automation and machinery applications. Rated at 7.5 kW (10 HP), it operates with a three-phase 380–480 V AC power supply and delivers a continuous output current of 15.5 A at 380–440 V and 14 A at 440–480 V.
Featuring an integrated H3 RFI filter, built-in brake chopper, and conformally coated PCB, the FC 51 combines reliable motor control, electromagnetic interference filtering, and dynamic braking functionality in a compact M3-frame design. Its IP20 chassis enclosure is intended for installation inside a suitable electrical control cabinet. The integrated brake chopper supports dynamic braking when connected to a compatible external braking resistor.
The drive supports open-loop motor control using VVC+ and U/f control modes, Automatic Motor Tuning (AMT), five programmable digital inputs, two analog inputs, a configurable analog/digital output, and one relay output. Built-in RS-485 communication supports Modbus RTU and Danfoss FC Protocol, enabling integration with compatible PLCs, industrial controllers, and automation systems.
The 132F0030 is supplied without a local control panel. Compatible Danfoss LCP 11 and LCP 12 control panels are available separately for local operation, commissioning, and parameter management.
The complete type code, FC-051P7K5T4E20H3BXCXXXSXXX, identifies the 7.5 kW three-phase 380–480 V configuration, IP20 enclosure, H3 RFI filter, integrated brake chopper, absence of a local control panel, conformally coated PCB, and standard cable-entry configuration.
Core Engineering Highlights:
7.5 kW / 10 HP rated power | Three-phase 380–480 V AC input | 15.5 A continuous output current (380–440 V) | 14 A continuous output current (440–480 V) | 23.5 A intermittent output current (380–440 V) | 21.3 A intermittent output current (440–480 V) | 150% overload capacity for 60 seconds | H3 RFI filter Class A1/B (C1) | Integrated brake chopper | Conformally coated PCB | IP20 chassis protection | M3 frame | 5 programmable digital inputs | 2 analog inputs | RS-485 with Modbus RTU and Danfoss FC Protocol
Key Features:
-
Original New Danfoss 132F0030 VLT Micro Drive FC 51 frequency converter.
-
7.5 kW / 10 HP rated output for three-phase 380–480 V AC industrial power supplies.
-
Continuous output current of 15.5 A at 380–440 V and 14 A at 440–480 V.
-
Intermittent output current of 23.5 A at 380–440 V and 21.3 A at 440–480 V.
-
150% overload capability for 60 seconds under the specified normal-overload operating conditions.
-
Integrated H3 RFI filter, Class A1/B (Category C1), for electromagnetic interference reduction.
-
Built-in brake chopper for dynamic braking with a compatible external braking resistor.
-
Conformally coated PCB for enhanced protection of internal electronics in demanding industrial environments.
-
Open-loop motor control with VVC+ and U/f control modes.
-
Automatic Motor Tuning (AMT) supports motor setup and commissioning.
-
Five programmable digital inputs with selectable PNP/NPN logic.
-
Two analog inputs support voltage and current reference signals.
-
One configurable analog/digital output provides drive monitoring and control signals.
-
One programmable relay output for external equipment status and control.
-
Built-in RS-485 communication supports Modbus RTU and Danfoss FC Protocol.
-
Compact M3 frame with IP20 chassis protection for electrical cabinet installation.
-
No local control panel included; optional Danfoss LCP 11 and LCP 12 control panels are available separately.
Applications:
-
Industrial pump and water circulation systems.
-
Ventilation fans and air-handling equipment.
-
Conveyor systems and material handling machinery.
-
Industrial production and processing equipment.
-
Packaging and manufacturing machinery.
-
Compressors and general-purpose motor applications.
-
Water treatment and wastewater equipment.
-
Automated production lines and PLC-controlled machinery.
-
Industrial equipment requiring variable-speed AC motor control.
-
Machinery requiring dynamic braking functionality.
Technical Specifications:
| Attribute | Specification |
|---|---|
| Catalog Number | 132F0030 |
| Complete Type Code | FC-051P7K5T4E20H3BXCXXXSXXX |
| Product Type Designation | VLT Micro Drive FC 51 |
| Product Family | Danfoss VLT Micro Drive |
| Product Category | Variable Frequency Drive (VFD) |
| Rated Power | 7.5 kW / 10 HP |
| Supply Phase | Three-phase |
| Input Voltage | 380–480 V AC |
| Input Frequency | 50/60 Hz |
| Continuous Input Current (380–440 V) | 24.8 A |
| Intermittent Input Current (380–440 V) | 36.3 A |
| Continuous Input Current (440–480 V) | 21.4 A |
| Intermittent Input Current (440–480 V) | 30.1 A |
| Continuous Output Current (380–440 V) | 15.5 A |
| Intermittent Output Current (380–440 V) | 23.5 A |
| Continuous Output Current (440–480 V) | 14 A |
| Intermittent Output Current (440–480 V) | 21.3 A |
| Overload Capacity | 150% for 60 seconds |
| Output Voltage | 0–100% of supply voltage |
| Output Frequency | 0–200 Hz (VVC+ mode); 0–400 Hz (U/f mode) |
| Motor Control | Open-Loop VVC+ / U/f |
| Motor Application | Three-phase AC Induction Motors |
| Motor Tuning | Automatic Motor Tuning (AMT) |
| RFI Filter | H3 – Class A1/B (Category C1) |
| Brake Chopper | Integrated |
| Braking Resistor | External, selected separately |
| Local Control Panel | Not Included |
| PCB Coating | Conformally Coated PCB |
| Mains Option | Not Included |
| Cable Entry | Standard Cable Entries |
| Enclosure Protection | IP20 / Chassis |
| Frame Size | M3 |
| Digital Inputs | 5 programmable |
| Digital Input Logic | PNP / NPN |
| Digital Input Voltage | 0–24 V DC |
| Analog Inputs | 2 |
| Analog Input Signals | 0–10 V / 0–20 mA / 4–20 mA |
| Analog / Digital Output | 1 configurable |
| Relay Outputs | 1 programmable SPDT relay |
| RS-485 Interface | 1 |
| Built-in Communication Protocols | Modbus RTU, Danfoss FC Protocol |
| Maximum Line / Motor Cable Size | 4 mm² / AWG 10 |
| Recommended Maximum Fuse | 40 A |
| Estimated Power Loss (Best Case) | 175 W |
| Estimated Power Loss (Typical) | 217.5 W |
| Efficiency (Best Case) | 98.0% |
| Efficiency (Typical) | 97.5% |
| Dimensions (H × W × D) | 239 × 90 × 194 mm |
| Height Including Decoupling Plate | 294 mm |
| Net Weight | Approximately 3.229 kg |
| Gross Weight | Approximately 3.646 kg |
| EAN / GTIN | 5702427357617 |
| Operating Temperature | Subject to drive derating and installation conditions |
| Maximum Relative Humidity | 95%, non-condensing |
| Maximum Altitude Without Derating | 1,000 m |
| Maximum Altitude With Derating | 3,000 m |
| EMC Standards | EN 61800-3, EN 55011 |
| Safety Standard | EN/IEC 61800-5-1 |
| Certifications | CE, cULus, RoHS |
Model Code Configuration:
| Code | Description |
|---|---|
| FC-051 | VLT Micro Drive FC 51 |
| P7K5 | 7.5 kW / 10 HP |
| T4 | Three-phase, 380–480 V AC |
| E20 | IP20 / Chassis |
| H3 | RFI Class A1/B (Category C1) |
| B | Integrated Brake Chopper |
| X | No Local Control Panel |
| C | Conformally Coated PCB |
| X | No Mains Option |
| X | Standard Cable Entries |
| X | No Additional Adaptation |
| SXXX | Latest Standard Software Release |
System Compatibility:
-
Designed for three-phase 380–480 V AC industrial electrical supply systems.
-
Suitable for compatible three-phase AC induction motors rated up to 7.5 kW.
-
Supports open-loop VVC+ vector control and U/f motor control.
-
Five programmable digital inputs support external start, stop, reset, reversing, and other drive-control commands.
-
PNP/NPN digital input logic provides flexibility for different control signal configurations.
-
Two analog inputs accommodate 0–10 V and 0/4–20 mA reference or feedback signals.
-
One configurable analog/digital output supports external monitoring and control functions.
-
One programmable relay output provides an additional equipment status or control interface.
-
Built-in RS-485 communication supports Modbus RTU and Danfoss FC Protocol integration with compatible PLCs and industrial controllers.
-
Integrated brake chopper supports dynamic braking when used with a suitably selected external braking resistor.
-
The H3 RFI filter supports Class A1/B (C1) electromagnetic compatibility under the specified installation conditions.
-
Conformally coated PCB provides additional protection for internal electronics in demanding industrial environments.
-
IP20 chassis design requires installation inside a suitable electrical control cabinet.
-
Compatible with optional Danfoss LCP 11 and LCP 12 control panels.
-
M3-frame installation accessories include the compatible decoupling plate and enclosure conversion kits.
-
Recommended maximum fuse rating is 40 A; the appropriate fuse type must be selected according to the applicable UL or non-UL installation requirements.
-
Confirm motor nameplate data, input voltage, overload requirements, braking resistor selection, EMC requirements, and installation clearances before replacing an existing drive.
Related Products:
-
132F0028 – Danfoss VLT Micro Drive FC 51 5.5 kW 380–480 V
-
132F0058 – Danfoss VLT Micro Drive FC 51 11 kW 380–480 V
-
132F0026 – Danfoss VLT Micro Drive FC 51 4.0 kW 380–480 V
-
132L6135 – Danfoss iC2-Micro 7.5 kW 380–480 V Frequency Converter with Brake Chopper
-
132B0100 – Danfoss VLT Control Panel LCP 11 without Potentiometer
-
132B0101 – Danfoss VLT Control Panel LCP 12 with Potentiometer
-
132B0102 – Danfoss VLT LCP Remote Mounting Kit with 3 m Cable
-
132B0105 – Danfoss Type 1 Enclosure Kit for M3 Frame
-
132B0107 – Danfoss Decoupling Plate Mounting Kit for M3 Frame
PLC ERA is an independent industrial automation distributor supplying genuine Original New products through established global supply channels. All products are factory sealed when applicable and undergo quality inspection prior to shipment. Danfoss and VLT are trademarks of Danfoss A/S.
Shipping Details & Duties: Please note that we ship directly from Shenzhen, China, under DAP (Delivered at Place) terms. This means buyers are fully responsible for paying all local import duties, taxes, and customs clearance fees upon arrival. If a package is refused or abandoned due to unpaid customs duties, taxes, or remote surcharges, the buyer will be held responsible for the original shipping fee, all return shipping costs, and any associated losses.
Share