Danfoss
131L4807 VLT AutomationDrive FC 302 11 kW 380–500 V Frequency Converter | Danfoss
131L4807 VLT AutomationDrive FC 302 11 kW 380–500 V Frequency Converter | Danfoss
Low stock: 9 left
Couldn't load pickup availability
The Original New Danfoss 131L4807 (FC-302P11KT5E20H2BXCXXXSXXXXA0BXCXXXXDX) VLT® AutomationDrive FC 302 is an advanced variable frequency drive designed for precise motor speed and torque control in industrial automation and machinery applications. Rated at 11 kW (15 HP) under high-overload operation, it operates with a three-phase 380–500 V AC power supply. It also supports up to 15 kW (20 HP) under normal-overload operating conditions.
Featuring an H2 RFI configuration, an IP20 chassis enclosure, and a B3 frame, the FC 302 is designed for installation inside suitable industrial electrical control cabinets. Its H2 configuration meets EN 55011 Class A2 and EN/IEC 61800-3 Category C3 requirements under specified installation conditions. An integrated brake chopper supports dynamic braking when connected to a compatible external braking resistor.
This configuration features a conformally coated PCB for enhanced protection of internal electronics and a factory-installed PROFIBUS DP-V1 MCA 101 communication option. The built-in PROFIBUS interface enables communication with compatible PLCs and industrial automation controllers. The drive is supplied without a local control panel, allowing the operator interface to be selected separately according to application requirements.
The FC 302 supports advanced VVC+ and Flux Vector Control for precise motor speed and torque regulation. Its programmable digital and analog interfaces, relay outputs, Smart Logic Controller, and built-in RS-485 communication provide flexible integration into industrial automation systems. A USB interface also supports PC-based parameter configuration, commissioning, and diagnostics.
The complete type code, FC-302P11KT5E20H2BXCXXXSXXXXA0BXCXXXXDX, identifies the 11 kW high-overload configuration, three-phase 380–500 V input, IP20 enclosure, H2 RFI configuration, integrated brake chopper, absence of a local control panel, conformally coated PCB, factory-installed PROFIBUS DP-V1 MCA 101 option, and no additional B, C, or D option cards.
Core Engineering Highlights:
11 kW / 15 HP high-overload rating | 15 kW / 20 HP normal-overload rating | Three-phase 380–500 V AC input | 24 A continuous output current (380–440 V, HO) | 21 A continuous output current (441–500 V, HO) | 38.4 A intermittent output current (380–440 V) | 33.6 A intermittent output current (441–500 V) | 160% high-overload capacity for 60 seconds | H2 RFI configuration Class A2 (C3) | Integrated brake chopper | Conformal-coated PCB | IP20 chassis protection | B3 frame | Factory-installed PROFIBUS DP-V1 MCA 101 | No local control panel
Key Features:
-
Original New Danfoss 131L4807 VLT AutomationDrive FC 302 frequency converter.
-
11 kW / 15 HP rated output under high-overload operating conditions.
-
Supports up to 15 kW / 20 HP under normal-overload operating conditions.
-
Three-phase 380–500 V AC power supply for industrial motor applications.
-
High-overload continuous output current of 24 A at 380–440 V and 21 A at 441–500 V.
-
High-overload intermittent output current of 38.4 A at 380–440 V and 33.6 A at 441–500 V.
-
Normal-overload continuous output current of 32 A at 380–440 V and 27 A at 441–500 V.
-
Integrated brake chopper supports dynamic braking with a compatible external braking resistor.
-
H2 RFI configuration meets Class A2 (Category C3) electromagnetic compatibility requirements under the specified installation conditions.
-
IP20 chassis enclosure with B3 frame for installation inside suitable electrical control cabinets.
-
Conformally coated PCB provides enhanced protection of internal electronics in demanding industrial environments.
-
Factory-installed PROFIBUS DP-V1 MCA 101 communication option for industrial fieldbus connectivity.
-
Supports cyclic process-data exchange and acyclic drive parameter access through compatible PROFIBUS networks.
-
Advanced VVC+ and Flux Vector Control functions support accurate motor speed and torque regulation.
-
Built-in Smart Logic Controller supports configurable drive-control sequences and application functions.
-
Programmable digital and analog interfaces support external references, feedback signals, and control commands.
-
Built-in RS-485 communication supports Danfoss FC Protocol and Modbus RTU.
-
USB interface supports PC-based drive configuration, parameter management, and monitoring.
-
Two programmable relay outputs provide additional equipment status and control interfaces.
-
No local control panel included; compatible Danfoss LCP control panels are available separately.
-
No additional B, C, or D option cards are factory-installed.
Applications:
-
Industrial machinery and automated production equipment.
-
Conveyor systems and material handling machinery.
-
Industrial pumps and fluid handling systems.
-
Ventilation fans and blowers.
-
Packaging and processing machinery.
-
Machine tools and manufacturing equipment.
-
Mixers and industrial processing systems.
-
Motor speed and torque control applications.
-
PLC-controlled production lines using PROFIBUS communication.
-
Factory automation and distributed control systems.
-
Industrial installations requiring dynamic braking and fieldbus-based drive integration.
Technical Specifications:
| Attribute | Specification |
|---|---|
| Catalog Number | 131L4807 |
| Complete Type Code | FC-302P11KT5E20H2BXCXXXSXXXXA0BXCXXXXDX |
| Product Type Designation | VLT AutomationDrive FC 302 |
| Product Family | Danfoss VLT AutomationDrive |
| Product Category | Variable Frequency Drive (VFD) |
| Rated Power – High Overload | 11 kW / 15 HP |
| Rated Power – Normal Overload | 15 kW / 20 HP |
| Supply Phase | Three-phase |
| Input Voltage | 380–500 V AC |
| Input Voltage Tolerance | ±10% |
| Input Frequency | 50/60 Hz |
| Continuous Input Current – HO (380–440 V) | 22 A |
| Intermittent Input Current – HO (380–440 V) | 35.2 A |
| Continuous Input Current – HO (441–500 V) | 19 A |
| Intermittent Input Current – HO (441–500 V) | 30.4 A |
| Continuous Output Current – HO (380–440 V) | 24 A |
| Intermittent Output Current – HO (380–440 V) | 38.4 A |
| Continuous Output Current – HO (441–500 V) | 21 A |
| Intermittent Output Current – HO (441–500 V) | 33.6 A |
| Continuous Output Current – NO (380–440 V) | 32 A |
| Intermittent Output Current – NO (380–440 V) | 35.2 A |
| Continuous Output Current – NO (441–500 V) | 27 A |
| Intermittent Output Current – NO (441–500 V) | 29.7 A |
| High-Overload Capacity | 160% for 60 seconds |
| Normal-Overload Capacity | 110% for 60 seconds |
| Continuous Apparent Power (400 V) | 16.6 kVA |
| Continuous Apparent Power (460 V) | 16.7 kVA |
| Output Voltage | 0–100% of supply voltage |
| Maximum Output Frequency | 590 Hz |
| Maximum Output Frequency in Flux Mode | 300 Hz |
| Motor Control | VVC+ / Flux Vector Control |
| Motor Application | Three-phase AC Motor Control |
| RFI Configuration | H2 – Class A2 (Category C3) |
| Integrated Brake Chopper | Yes |
| Braking Resistor | External, selected separately |
| Local Control Panel | Not Included |
| PCB Coating | Conformal-Coated PCB |
| Mains Option | Not Included |
| Cable Entry Configuration | Standard Cable Entries |
| Additional Adaptation | Not Included |
| A Option | A0 – PROFIBUS DP-V1 MCA 101 |
| B Option | BX – No Additional B Option |
| C0 / MCO Option | CX – No Option |
| C1 Option | X – No Option |
| C Option Software | XX – Standard Controller |
| D Option | DX – No Option |
| Enclosure Protection | IP20 / Chassis |
| Frame Size | B3 |
| Digital Inputs | 6 programmable |
| Digital Input Logic | PNP / NPN |
| Analog Inputs | 2 programmable |
| Analog Input Signals | Voltage / Current |
| Analog Outputs | 1 programmable |
| Digital Outputs | 2 programmable |
| Relay Outputs | 2 programmable |
| RS-485 Interface | 1 |
| USB Interface | 1 |
| Factory-Installed Fieldbus Option | PROFIBUS DP-V1 MCA 101 |
| PROFIBUS Communication | PROFIBUS DP V0 / DP V1 |
| PROFIBUS Master Support | Class 1 / Class 2 |
| Built-in Communication Protocols | PROFIBUS DP-V1, Danfoss FC Protocol, Modbus RTU |
| Smart Logic Controller | Integrated |
| Estimated Power Loss at Rated Maximum Load | 291 W |
| Efficiency at Rated Output Current | Approximately 98% |
| Maximum Cable Cross-Section (IP20) | 10 mm² / AWG 8 |
| Net Weight | Approximately 11.056 kg |
| Gross Weight | Approximately 11.356 kg |
| Product Volume | Approximately 42.336 L |
| EAN / GTIN | 5702427756403 |
| EMC Standard | EN 61800-3 |
| EMC Category | C3 |
| Conducted Emissions Classification | EN 55011 Class A2 |
| Safety Standard | EN/IEC 61800-5-1 |
| Export Classification (EU) | Y901 |
| Export Classification (US) | 3A999.a |
Model Code Configuration:
| Code | Description |
|---|---|
| FC-302 | VLT AutomationDrive FC 302 |
| P11K | 11 kW / 15 HP High-Overload Rating |
| T5 | Three-phase, 380–500 V AC |
| E20 | IP20 / Chassis |
| H2 | RFI Class A2 (Category C3) |
| B | Integrated Brake Chopper |
| X | No Local Control Panel |
| C | Conformal-Coated PCB |
| X | No Mains Option |
| X | Standard Cable Entries |
| X | No Additional Adaptation |
| SXXX | Latest Standard Software Release |
| X | Standard Language Package |
| A0 | PROFIBUS DP-V1 MCA 101 Communication Option |
| BX | No Additional B Option |
| CX | No C0 / MCO Option |
| X | No C1 Option |
| XX | Standard Controller Software |
| DX | No D Option |
System Compatibility:
-
Designed for three-phase 380–500 V AC industrial electrical supply systems.
-
Suitable for compatible three-phase AC motors rated up to 11 kW under high-overload operation or 15 kW under normal-overload operation.
-
Supports VVC+ and Flux Vector Control for advanced motor speed and torque regulation.
-
High-overload operation supports 160% intermittent output current for 60 seconds under the specified operating conditions.
-
Normal-overload operation supports 110% intermittent output current for 60 seconds.
-
Factory-installed PROFIBUS DP-V1 MCA 101 enables communication with compatible PROFIBUS PLCs and industrial automation controllers.
-
PROFIBUS DP V0 supports cyclic process-data exchange for drive commands, speed references, and status information.
-
PROFIBUS DP-V1 supports acyclic parameter access for configuration, commissioning, and monitoring.
-
Master Class 1 communication supports PLC-based drive control and cyclic data exchange.
-
Master Class 2 communication supports parameterization and commissioning through compatible engineering tools.
-
Built-in RS-485 communication supports Danfoss FC Protocol and Modbus RTU serial communication.
-
Six programmable digital inputs support external start, stop, reset, and other drive-control commands.
-
Two programmable analog inputs accommodate voltage and current reference or feedback signals.
-
One programmable analog output and two digital outputs support external monitoring and control functions.
-
Two programmable relay outputs provide additional equipment status and control interfaces.
-
The integrated Smart Logic Controller supports configured automation and drive-control sequences.
-
The integrated brake chopper supports dynamic braking when connected to a suitably selected external braking resistor.
-
The H2 RFI configuration meets Class A2 (C3) EMC requirements under the specified installation conditions; confirm cable length, grounding, and system installation requirements.
-
Conformal-coated PCB provides additional protection for internal electronics in demanding industrial environments.
-
IP20 chassis design requires installation inside a suitable electrical control cabinet.
-
No local control panel is included; compatible Danfoss LCP accessories can be added for local operation and commissioning.
-
Confirm motor nameplate ratings, overload requirements, PROFIBUS network configuration, braking resistor selection, EMC requirements, and installation clearances before commissioning or replacement.
Related Products:
-
130B1100 – Danfoss VLT PROFIBUS DP-V1 MCA 101 Communication Option Card
-
130B1107 – Danfoss VLT Control Panel LCP 102 Graphical Local Control Panel
-
130B1124 – Danfoss VLT Control Panel LCP 101 Numerical Local Control Panel
-
130B1135 – Danfoss VLT PROFINET MCA 120 Communication Option Card
-
130B1119 – Danfoss VLT EtherNet/IP MCA 121 Communication Option Card
-
130B1196 – Danfoss VLT Modbus TCP MCA 122 Communication Option Card
-
130B1000 – Danfoss MCT 10 Set-up Software
-
Danfoss VLT Brake Resistors – External Dynamic Braking Accessories
PLC ERA is an independent industrial automation distributor supplying genuine Original New products through established global supply channels. All products are factory sealed when applicable and undergo quality inspection prior to shipment. Danfoss, VLT, and AutomationDrive are trademarks of Danfoss A/S.
Shipping Details & Duties: Please note that we ship directly from Shenzhen, China, under DAP (Delivered at Place) terms. This means buyers are fully responsible for paying all local import duties, taxes, and customs clearance fees upon arrival. If a package is refused or abandoned due to unpaid customs duties, taxes, or remote surcharges, the buyer will be held responsible for the original shipping fee, all return shipping costs, and any associated losses.
Share