Skip to product information
1 of 2

Danfoss

131B0001 VLT AutomationDrive FC 302 4 kW 380–500 V Frequency Converter | Danfoss

131B0001 VLT AutomationDrive FC 302 4 kW 380–500 V Frequency Converter | Danfoss

13 in stock

Regular price $820.00 USD
Regular price Sale price $820.00 USD
Sale Sold out
Shipping calculated at checkout.

The Original New Danfoss 131B0001 (FC-302P4K0T5E20H1XXXXXXSXXXXAXBXCXXXXDX) VLT® AutomationDrive FC 302 is an advanced variable frequency drive designed for precise motor speed and torque control in industrial automation and machinery applications. Rated at 4.0 kW (5 HP), it operates with a three-phase 380–500 V AC power supply and supports high-overload operation for demanding motor-control applications.

Featuring an integrated H1 RFI filter, Class A1/B (Category C1), an IP20 chassis enclosure, and a compact A2 frame, the FC 302 provides reliable motor control and electromagnetic interference filtering for industrial installations. This configuration is supplied without a brake chopper, local control panel, or additional mains option. It also uses an uncoated PCB configuration for conventional industrial operating environments.

The FC 302 supports advanced VVC+ and Flux Vector Control functions for accurate motor speed and torque regulation. Its built-in Smart Logic Controller, programmable analog and digital inputs, relay outputs, and RS-485 communication support integration with compatible PLCs and industrial automation controllers. The USB interface provides convenient PC connectivity for drive configuration, parameter management, and diagnostics.

The complete type code, FC-302P4K0T5E20H1XXXXXXSXXXXAXBXCXXXXDX, identifies the 4 kW three-phase configuration, IP20 enclosure, H1 RFI filter, absence of an integrated brake chopper and local control panel, uncoated PCB, standard cable entries, and no additional A, B, C, or D option cards.

Core Engineering Highlights:

4 kW / 5 HP rated power | Three-phase 380–500 V AC input | 10 A continuous output current (380–440 V) | 8.2 A continuous output current (441–500 V) | 16 A intermittent output current (380–440 V) | 13.1 A intermittent output current (441–500 V) | 160% high-overload capacity for 60 seconds | H1 RFI filter Class A1/B (C1) | IP20 chassis protection | A2 frame | Built-in Smart Logic Controller | RS-485 and USB interfaces | No integrated brake chopper | No local control panel | Uncoated PCB

Key Features:

  • Original New Danfoss 131B0001 VLT AutomationDrive FC 302 frequency converter.

  • 4.0 kW / 5 HP rated output for three-phase 380–500 V AC industrial power supplies.

  • Continuous output current of 10 A at 380–440 V and 8.2 A at 441–500 V.

  • Intermittent output current of 16 A at 380–440 V and 13.1 A at 441–500 V.

  • 160% high-overload capability for 60 seconds, suitable for demanding industrial motor applications.

  • Integrated H1 RFI filter, Class A1/B (Category C1), for electromagnetic interference reduction.

  • IP20 chassis enclosure with compact A2 frame for electrical cabinet installation.

  • Advanced VVC+ and Flux Vector Control functions support accurate motor speed and torque regulation.

  • Built-in Smart Logic Controller helps execute configurable drive-control functions without requiring additional PLC hardware for every application.

  • Programmable digital and analog interfaces support external references, feedback signals, and control commands.

  • Built-in RS-485 communication supports Danfoss FC Protocol and Modbus RTU.

  • USB interface supports PC-based drive configuration, parameter management, and monitoring.

  • Integrated motor protection and monitoring functions support reliable operation.

  • No integrated brake chopper; an external braking solution must be evaluated separately where dynamic braking is required.

  • No local control panel included; compatible Danfoss LCP control panels are available separately.

  • Uncoated PCB configuration, suitable for conventional industrial installation environments.

Applications:

  • Industrial machinery and automated production equipment.

  • Conveyor systems and material handling machinery.

  • Positioning and synchronization applications.

  • Industrial pumps and fluid handling systems.

  • Ventilation fans and blowers.

  • Packaging and processing machinery.

  • Mixers, centrifuges, and manufacturing equipment.

  • Machine tools and automated production lines.

  • PLC-controlled motor speed and torque regulation.

  • Industrial automation systems requiring flexible drive configuration.

Technical Specifications:

Attribute Specification
Catalog Number 131B0001
Complete Type Code FC-302P4K0T5E20H1XXXXXXSXXXXAXBXCXXXXDX
Product Type Designation VLT AutomationDrive FC 302
Product Family Danfoss VLT AutomationDrive
Product Category Variable Frequency Drive (VFD)
Rated Power 4.0 kW / 5 HP
Supply Phase Three-phase
Output Phase Three-phase
Input Voltage 380–500 V AC
Input Voltage Tolerance ±10%
Input Frequency 50/60 Hz ±5%
Continuous Output Current (380–440 V) 10 A
Intermittent Output Current (380–440 V) 16 A
Continuous Output Current (441–500 V) 8.2 A
Intermittent Output Current (441–500 V) 13.1 A
High-Overload Capacity 160% for 60 seconds
Continuous Apparent Power (400 V) 6.93 kVA
Continuous Apparent Power (460 V) 6.5 kVA
Output Voltage 0–100% of supply voltage
Maximum Output Frequency 590 Hz
Motor Control VVC+ / Flux Vector Control
Motor Application Three-phase AC motor control
RFI Filter H1 – Class A1/B (Category C1)
Brake Chopper Not Included
Braking Resistor Not Included
Local Control Panel Not Included
PCB Coating Uncoated PCB
Mains Option Not Included
Adaptation A Standard Cable Entries
Adaptation B No Additional Adaptation
A Option Not Included
B Option Not Included
C0 / MCO Option Not Included
C1 Option Not Included
C Option Software Not Included
D Option Not Included
Enclosure Protection IP20 / Chassis
Frame Size A2
Digital Inputs 6 programmable
Digital Input Logic PNP / NPN
Analog Inputs 2 programmable
Analog Input Signals Voltage / Current
Analog Outputs 1 programmable
Digital Outputs 2 programmable
Relay Outputs 2 programmable
RS-485 Interface 1
USB Interface 1
Built-in Communication Protocols Danfoss FC Protocol, Modbus RTU
Smart Logic Controller Integrated
Motor Thermal Protection Electronic Motor Thermal Protection
Estimated Power Loss (High Overload) 124 W
Dimensions (H × W × D) 268 × 90 × 205 mm
Depth with A/B Options 220 mm
Width with Two C Options 150 mm
Net Weight Approximately 4.5 kg
Gross Weight Approximately 5.346 kg
EAN / GTIN 5702427090569
Maximum Ambient Temperature 50°C, subject to installation conditions and derating
EMC Standard EN 61800-3
Safety Standard EN/IEC 61800-5-1
Export Classification (EU) Y901
Export Classification (US) 3A999.a

Model Code Configuration:

Code Description
FC-302 VLT AutomationDrive FC 302
P4K0 4.0 kW / 5 HP
T5 Three-phase, 380–500 V AC
E20 IP20 / Chassis
H1 RFI Class A1/B (Category C1)
X No Integrated Brake Chopper
X No Local Control Panel
X Uncoated PCB
X No Mains Option
X Standard Cable Entries
X No Additional Adaptation
SXXXX Latest Standard Software Release
X Standard Language Pack
AX No A Option
BX No B Option
CX No C0 / MCO Option
X No C1 Option
XX No C Software Option
DX No D Option

System Compatibility:

  • Designed for three-phase 380–500 V AC industrial electrical supply systems.

  • Suitable for compatible three-phase AC motors rated up to 4.0 kW under the specified high-overload operating conditions.

  • Supports VVC+ and Flux Vector Control for advanced motor speed and torque regulation.

  • High-overload operation supports up to 160% intermittent output current for 60 seconds.

  • Built-in RS-485 communication supports Modbus RTU and Danfoss FC Protocol integration with compatible PLCs and industrial controllers.

  • Two programmable analog inputs accommodate voltage and current reference or feedback signals.

  • Six programmable digital inputs support external start, stop, reset, and other drive-control commands.

  • Programmable analog and digital outputs support external monitoring and control functions.

  • Two programmable relay outputs provide additional equipment status and control interfaces.

  • The integrated Smart Logic Controller supports configured automation and drive-control sequences.

  • The USB interface supports PC connection for drive configuration, parameter management, and diagnostics.

  • The H1 RFI filter provides Class A1/B (C1) electromagnetic compatibility under the specified installation conditions.

  • IP20 chassis design requires installation inside a suitable electrical control cabinet.

  • No integrated brake chopper is included in this configuration; verify external braking requirements before selecting a replacement.

  • No local control panel is supplied; compatible Danfoss LCP accessories are available separately.

  • No additional fieldbus or functional option cards are factory-installed.

  • The uncoated PCB configuration is intended for conventional industrial operating environments.

  • Confirm motor nameplate ratings, overload requirements, input voltage, EMC requirements, braking requirements, and installation clearances before commissioning or replacement.

Related Products:

  • 131B0002 – Danfoss VLT AutomationDrive FC 302 5.5 kW 380–500 V IP20

  • 131B0003 – Danfoss VLT AutomationDrive FC 302 7.5 kW 380–500 V IP20

  • 131B0006 – Danfoss VLT AutomationDrive FC 302 4 kW 380–500 V with Integrated Brake Chopper

  • 130B1107 – Danfoss VLT Control Panel LCP 102 Graphical Local Control Panel

  • 130B1124 – Danfoss VLT Control Panel LCP 101 Numerical Local Control Panel

  • 130B1100 – Danfoss VLT PROFIBUS DP V1 MCA 101 Communication Option Card

  • 130B1135 – Danfoss VLT PROFINET MCA 120 Communication Option Card

  • 130B1119 – Danfoss VLT EtherNet/IP MCA 121 Communication Option Card

  • 130B1196 – Danfoss VLT Modbus TCP MCA 122 Communication Option Card

PLC ERA is an independent industrial automation distributor supplying genuine Original New products through established global supply channels. All products are factory sealed when applicable and undergo quality inspection prior to shipment. Danfoss, VLT, and AutomationDrive are trademarks of Danfoss A/S.

Shipping Details & Duties: Please note that we ship directly from Shenzhen, China, under DAP (Delivered at Place) terms. This means buyers are fully responsible for paying all local import duties, taxes, and customs clearance fees upon arrival. If a package is refused or abandoned due to unpaid customs duties, taxes, or remote surcharges, the buyer will be held responsible for the original shipping fee, all return shipping costs, and any associated losses.

View full details