Mitsubishi Electric AJ65SBTB1-16DT is a terminal block type remote I/O module for CC-Link fieldbus networks. It is a combined module with 8 digital inputs and 8 sink‑type transistor outputs, designed for MELSEC‑A series distributed control systems. The module provides 16 I/O points in a compact 130 mm width enclosure, reducing field wiring and simplifying cabinet installation. Finger protection on the terminal block allows direct mounting on machinery without additional covers. CE, UL, cUL certified.
Applications:
-
Distributed machine I/O control via CC‑Link networks
-
Remote control panels and automated production lines
-
Packaging machinery and material handling systems
-
OEM equipment requiring CC‑Link remote I/O expansion
Technical Specifications:
Digital Inputs
-
Number of points: 8
-
Input type: DC input, positive common (sink, compatible with NPN sensors)
-
Rated input voltage: 24 V DC (19.2 … 26.4 V, ripple ≤ 5 %)
-
Rated input current: 7 mA (approx.)
-
Input resistance: 3.3 kΩ
-
ON voltage / ON current: ≥ 14 V / ≥ 3.5 mA
-
OFF voltage / OFF current: ≤ 6 V / ≤ 1.7 mA
-
Response time: ≤ 1.5 ms (at 24 V DC)
-
Isolation: Photocoupler insulation
-
Simultaneously ON points: 100 %
-
External connection: 1‑wire type, 18‑point direct mounting terminal block (M3 × 5.2 screws)
Digital Outputs
-
Number of points: 8
-
Output type: Transistor output, sink (leakage type)
-
Rated load voltage: 24 V DC (19.2 … 26.4 V, ripple ≤ 5 %)
-
Maximum load current: 0.5 A per point, 1.2 A per common
-
Inrush current: 1.0 A / 10 ms max.
-
OFF leakage current: 0.25 mA max.
-
ON voltage drop: 0.3 V typ., 0.6 V max. at 0.5 A
-
Response time (resistive load): OFF→ON ≤ 0.5 ms, ON→OFF ≤ 1.5 ms
-
Surge suppressor: Zener diode
-
Protection: Overload, overvoltage, overheat protection (built‑in)
-
Common arrangement: 16 points / 1 common (terminal block type, 3‑wire)
-
External connection: 18‑point direct mounting terminal block (M3 × 5.2 screws)
CC‑Link Communication
-
CC‑Link version: Ver. 1.10 compliant
-
Station type: Remote I/O station (device station)
-
Occupied stations: 1 (allocates 32 points, uses 16 points)
-
Transmission speed: Supports CC‑Link baud rates up to 10 Mbps (dependent on system configuration)
-
Connection terminal: Communications and I/O module power: 7‑point, 2‑section terminal block
Power Supply
-
I/O module power supply voltage: 24 V DC (20.4 … 26.4 V, ripple ≤ 5 %)
-
I/O module power supply current: ≤ 50 mA at 24 V DC (all points ON, excluding external load current)
-
Output external supply current: ≤ 17.8 mA at 24 V DC (all points ON, excluding external load current)
Environmental & Physical
-
Withstand voltage: 500 V AC for 1 min between DC external terminals and ground
-
Insulation resistance: ≥ 10 MΩ at 500 V DC (insulation resistance tester)
-
Noise immunity: 500 Vp‑p, 1 µs noise width, 25 … 60 Hz noise frequency (noise simulator)
-
Protection rating: IP2X
-
Weight: 0.18 kg
-
Dimensions (W × H × D): approx. 130 mm × 45 mm × 85 mm
-
Operating temperature: 0 °C … 55 °C
-
Storage temperature: –20 °C … 70 °C
-
Mounting: 6‑direction mounting, DIN rail compatible (TH35‑7.5Fe or TH35‑7.5Al per JIS C 2812)
-
Mounting screw: M4 with flat washer (tightening torque 79 … 108 N·cm)
-
Terminal tightening torque (M3 screws): 59 … 88 N·cm
-
Applicable crimp terminal: RAV1.25‑3
System Integration:
-
This remote I/O module belongs to the Mitsubishi Electric MELSEC‑A series CC‑Link system.
-
Connects to the CC‑Link network as a remote I/O station (1 occupied station).
-
Compatible with MELSEC‑A, QnA, AnS, and Q series CC‑Link master modules (e.g., QJ61BT11N).
-
Up to 64 remote I/O units can be connected to a single CC‑Link master station.
-
The module can be mounted directly on the machine frame using the 6‑direction mounting capability.
-
Finger protection on the terminal block enables safe installation without additional covers.
Standards & Compliance:
Refer to manufacturer official documentation for detailed certification and compliance information (CE, UL, cUL, RoHS).
Related Products:
-
AJ65SBTB1-8D – 8‑point DC input remote I/O module
-
AJ65SBTB1-16T – 16‑point transistor output remote I/O module
-
AJ65SBTB1-32DT – 32‑point DC input / transistor output remote I/O module
-
QJ61BT11N – CC‑Link master module for MELSEC‑Q series
-
AJ65SBTB1-16DT1 – Variant with different input specification
Share